Back Button DAC60004IPWR Datasheet HTML 25Page - Texas Instruments DAC60004IPWR Datasheet HTML 26Page - Texas Instruments DAC60004IPWR Datasheet HTML 27Page - Texas Instruments DAC60004IPWR Datasheet HTML 28Page - Texas Instruments DAC60004IPWR Datasheet HTML 29Page - Texas Instruments DAC60004IPWR Datasheet HTML 30Page - Texas Instruments DAC60004IPWR Datasheet HTML 31Page - Texas Instruments DAC60004IPWR Datasheet HTML 32Page - Texas Instruments DAC60004IPWR Datasheet HTML 33Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 44 page
background image
29
DAC80004, DAC70004, DAC60004
www.ti.com
SLASED6D – APRIL 2016 – REVISED DECEMBER 2017
Product Folder Links: DAC80004 DAC70004 DAC60004
Submit Documentation Feedback
Copyright © 2016–2017, Texas Instruments Incorporated
11 Layout
11.1 Layout Guidelines
A precision analog component requires careful layout, adequate bypassing, and clean, well-regulated power
supplies. As a general rule it is important to keep digital traces as far away from analog traces when possible.
The DACx0004 is often used in close proximity with digital logic, microcontrollers, microprocessors, and digital
signal processors. The more digital logic present in the design and the higher the switching speed, the more
difficult it is to keep digital noise from appearing at the output.
Due to the single ground pin of the DACx0004, all return currents, including digital and analog return currents for
the DAC, must flow through a single point. Ideally, GND must be connected directly to an analog ground plane.
This plane must be separate from the ground connection for the digital components until they were connected at
the power-entry point of the system.
As with the GND connection, VDD should be connected to a 5 V power-supply plane or trace that is separate
from the connection for digital logic until they are connected at the power-entry point. It is recommended to have
an additional 1 μF to 10 μF capacitor and 0.1 μF bypass capacitor. In some situations, additional bypassing may
be required, such as a 100 μF electrolytic capacitor or even a Pi filter made up of inductors and capacitors—all
designed to essentially low-pass filter the 5 V supply, removing the high-frequency noise. In general it is always a
good idea to maintain the digital signals away from analog signals.
11.2 Layout Example
Figure 60. Layout Diagram



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com