전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

L9908TR 데이터시트(PDF) 35 Page - STMicroelectronics

부품명 L9908TR
상세설명  Automotive 3-Phase motor gate driver unit
PDF  152 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  STMICROELECTRONICS [STMicroelectronics]
홈페이지  http://www.st.com
Logo STMICROELECTRONICS - STMicroelectronics

L9908TR 데이터시트(HTML) 35 Page - STMicroelectronics

Back Button L9908TR Datasheet HTML 31Page - STMicroelectronics L9908TR Datasheet HTML 32Page - STMicroelectronics L9908TR Datasheet HTML 33Page - STMicroelectronics L9908TR Datasheet HTML 34Page - STMicroelectronics L9908TR Datasheet HTML 35Page - STMicroelectronics L9908TR Datasheet HTML 36Page - STMicroelectronics L9908TR Datasheet HTML 37Page - STMicroelectronics L9908TR Datasheet HTML 38Page - STMicroelectronics L9908TR Datasheet HTML 39Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 35 / 152 page
background image
In CONFIG mode a dedicated configuration bit is present for each one of the configurable reaction faults to mask
output redirection as follows:
Table 29. Fault output redirection configuration bit
<FLT_REF>_REDIRECT_CFG
Description
0
Fault redirected on FS_FLAG/IC ERR (Default)
1
Fault redirection masked
Figure 14. Fault output redirection logic simplified block diagram
5.6.2
Fault reaction scenarios
Here below are described the scenarios of each different fault case separately.
In case multiple faults take place at the same time the following priority in reaction is used:
•
STD fault
•
Auto-retry
•
Reduced operation mode
•
WRN fault
5.6.2.1
Shutdown faults
When a shutdown fault is detected, the related SPI flag is set to ‘1’, the IC ERR bits in the SPI FRAME are set to
‘11’ and the FS_FLAG is asserted low.
Disable logic reacts by establishing SAFE_OFF mode: all the three half bridges are disabled, with VGHS_n-
VSHS_n = 0 V and VGLS_n-VSLSn = 0V [n = 1, 2, 3]. Gate Drive Supply block is disabled (SPI configuration bit
HBn_DIS, CP1_EN and CP2_EN remain set as previously configured).
The SAFE_OFF mode can be left when all the following conditions are met in the following sequence:
1. STD fault is removed;
2. STD fault flag is cleared on read (action required by Application SW);
3. EN_BR is asserted low for at least T_clear and then asserted back high (action required by Application SW).
L9908
Functional description
DS13546 - Rev 5
page 35/152



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com