| 전자부품 데이터시트 검색엔진 |
|
VNF1048F 데이터시트(PDF) 17 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
VNF1048F 데이터시트(HTML) 17 Page - STMicroelectronics |
|
17 / 49 page ![]() Figure 6. Current sense self-test flow sequence Current sense Self-test Configuration CR#1→ S_T_CFG = --1 CR#2→ OVC_THR = <user option> CR#2 →HSHT_THR = <user option> SELF-TEST CONFIGURATION Turn-on pull-down current generator to produce additional voltage drop of 100 mV on current sense amplifier inputs A/D CONVERSIONS AND DELTA MEASURES Perform current sense SAR A/D conversions Compute difference between self-test measures and last user measure available in status register SR#8 Store data result, self-test status and fault emulation check in status register SR#7 UNLOCKED STATE SELF-TEST STATE Current sense Self-test Execution Current sense Self-test END UNLOCKED STATE S_T_START = 1 LOCKED S_T_STOP = 1 WD Timeout OR HWLO = 1 TS_T_ACTIVE time duration CURRENT SENSE SELF-TEST SELF-TEST CLOSURE Turn-off pull-down current generator to restore normal drop on current sense amplifier inputs No current sense A/D conversions during this timeframe TS_T_WAITtime duration During TS_T_ACTIVE and TS_T_WAIT timeframes, fast and slow trip protections are inhibited, whilst all other protections are active 00 = IDLE 01 = RUN 10 = END 11 = ABORT 14 14 00 Parity Status ADC Self Test Result OVC_ST HSHT_ST (Selftest aborted, state transition after TS_T_WAIT expiration) (Selftest aborted, state transition after TS_T_WAIT expiration) TEST COMPLETED TS_T_ACTIVE = 5 μs TS_T_WAIT = 5 μs Current sense Self-test Configuration 4.2 External FET VDS detection self-test The purpose of the external FET VDS detection self-test is to verify the proper behavior of the complete VDS monitor chain (sense/process/detection), from the analog input to the digital output. Starting from the unlocked state, the VDS detection self-test is activated through a dedicated SPI frame. The duration of this test is around 10 μs; the first 5 μs are intended to convert the value of the voltage across the drain and source terminals of the external FET, the remaining 5 µs are required to bring back the analog circuitry to normal configuration. Once the self-test is started, an internal current generator provides a current sink able to produce an additional voltage offset of 100 mV on VDS monitor circuit inputs, to distinguish self-test execution from normal operation. In order to guarantee proper data conversions, special care must be taken to avoid VDS ADC saturation by keeping the overall VDS sensed by the monitor circuit below the maximum scale range (VDS_ADC_CONV). VDS detection self-test result is the difference between the converted value obtained during self-test execution and the value already stored in SR#4 (VDS field), corresponding to the normal measurement performed during operation; such delta measure result is stored in SR#5 (S_T_VDS field) together with the self-test status. VNF1048F Self-test DS13084 - Rev 8 page 17/49 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |