| 전자부품 데이터시트 검색엔진 |
|
EFS2BCD 데이터시트(PDF) 9 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
EFS2BCD 데이터시트(HTML) 9 Page - STMicroelectronics |
|
9 / 14 page ![]() EFS 9/14 5/ THE DRIVER: FUNCTIONAL DESCRIPTION GND G1 G2 Preheat Select Vcc Shunt State tube Minimum Power supply State tube detection (Striked / Off) 0 current synchro ISO synchro 350mA Pre-heat period counter 1,5s or 2.5s Current generator 30mA 8 attempts Strikes counter UVLO Clock 1/8 EFS2A DRIVER Internal block diagram (50Hz operation) ALGORITHM 1. At switch on: At switch on, an integrated Under Voltage Lock Out function (UVLO) resets the driver as long as the supply voltage stays below a safety level. 2. Preheat: The ignition sequence begins with the preheat phase. Two different duration’s can be selected with PIN 2 (see table EFS STARLIGHT-KIT PARTS SELECTION page 2). During this phase, the driver maintains the ASD ™ in a full ON-state making the starter equivalent to a bi-directional conducting switch. 3. Ignition of the fluorescent tube: At the end of the preheat period, the starter strikes the fluorescent lamp. For that, the driver reads continuously the current through the starter. When the current reaches the Switch Off level (ISO = 350mA), the driver turns off the ASD ™. This induces a high voltage pulse across the lamp. This pulse amplitude is limited by the ASD ™ (′1350V). 4. If the lamp fails to strike: The driver detects the state of the tube (lit or off). If it stays off during 8 mains cycles (loop 1), a new preheat period, shorter than the first one, starts again (loop 3), followed by a new ignition attempt. The driver will try to fire the tube 8 times. If none of the 8 attempts succeeds in striking the lamp, the driver turns in standby mode, and the whole starter is fully stopped until the next mains removal and power supply reset. 5. If the lamp is ignited: If the lamp is ignited, the driver stays in standby mode while monitoring the state of the lamp (loop 2). During normal operation of the tube, this short pulse is masked by the lamp conduction. If the mains interruption is really long enough to turn off completely the lamp, a new ignition sequence starts again (loop 3) with 8 other new possible attempts. AC MAINS ON UVLO RESET Preheat * 1.5s or 2.5s Strike Attempt = Attempt + 1 Preheat * 0.75s or 1.25s Attempt <8 YES YES YES NO NO NO Loop 3 Loop 2 Tube Ignited? Fail = Fail + 1 Fail = 8 Fail = 0 Autosupply Autosupply Fail = 0 Attempt = 0 * see the preheat duration table § 6 Loop 1 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |