Back Button GS-D200S Datasheet HTML 4Page - STMicroelectronics GS-D200S Datasheet HTML 5Page - STMicroelectronics GS-D200S Datasheet HTML 6Page - STMicroelectronics GS-D200S Datasheet HTML 7Page - STMicroelectronics GS-D200S Datasheet HTML 8Page - STMicroelectronics GS-D200S Datasheet HTML 9Page - STMicroelectronics GS-D200S Datasheet HTML 10Page - STMicroelectronics GS-D200S Datasheet HTML 11Page - STMicroelectronics GS-D200S Datasheet HTML 12Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 17 page
background image
8/17
PHASE SEQUENCE GENERATION INSIDE THE
GS-D200/GS-D200S
The modules contains a three bit counter plus
some combinational logic which generate suitable
phase sequences for half step, wave and normal
full step drive. This 3 bit counter generates a basic
eight-step Gray code master sequence as shown
in fig. 9. To select this sequence, that corresponds
to half step mode, the HALF/FULL input (pin 4)
must be kept high or unconnected.
The full step mode (normal and wave drive) are
both obtained from the eight step master sequence
by skipping alternate states. This is achieved by
forcing the step clock to bypass the first stage of
the 3 bit counter. The least significant bit of this
counter is not affected and therefore the generated
sequence depends on the state of the counter
when full step mode is selected by forcing pin 4
(HALF/FULL) low. If full step is selected when the
counter is at any odd-numbered state, the two-
phase-on (normal mode) is implemented (see fig.
10).
On the contrary, if the full mode is selected when
the counter is at an even-numbered state, the
one-phase-on (wave drive) is implemented (see
fig. 11).
Figure 9: The Eight Step Master Sequence corresponding to Half Step Mode.
GS-D200/GS-D200S



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com