| 전자부품 데이터시트 검색엔진 |
|
TMP461-EP 데이터시트(PDF) 23 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP461-EP 데이터시트(HTML) 23 Page - Texas Instruments |
|
23 / 38 page ![]() TMP461 D+ D- SCL SDA THERM GND V+ ALERT / THERM2 SMBus Controller 1 2 3 4 6 9 8 7 1.7V to 3.6V Over-Temperature Shutdown 10 5 A1 A0 RS (2) RS (2) RS (2) RS (2) CDIFF (3) CDIFF (3) Transistor-connected configuration (1) Diode-connected configuration (1) Series Resistance 0.1µF 10k (typ) 10k (typ) 10k (typ) 10k (typ) 23 TMP461 www.ti.com SBOS722B – JUNE 2015 – REVISED AUGUST 2016 Product Folder Links: TMP461 Submit Documentation Feedback Copyright © 2015–2016, Texas Instruments Incorporated 9 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 9.1 Application Information The TMP461 device requires only a transistor connected between the D+ and D– pins for remote temperature measurement. Tie the D+ pin to GND if the remote channel is not used and only the local temperature is measured. The SDA, ALERT, and THERM pins (and SCL, if driven by an open-drain output) require pullup resistors as part of the communication bus. A 0.1-µF power-supply decoupling capacitor is recommended for local bypassing. Figure 18 and Figure 19 illustrate the typical configurations for the TMP461 device. 9.2 Typical Application (1) The diode-connected configuration provides better settling time. The transistor-connected configuration provides better series resistance cancellation. (2) RS (optional) is < 1 kΩ in most applications. RS is the combined series resistance connected externally to the D+, D- pins. RS selection depends on the application; see the Filtering section. (3) CDIFF (optional) is < 1000 pF in most applications. CDIFF selection depends on the application; see the Filtering section and Figure 6 (Remote Temperature Error vs Differential Capacitance). Figure 18. TMP461 Basic Connections Using a Discrete Remote Transistor |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |