| 전자부품 데이터시트 검색엔진 |
|
1908 데이터시트(PDF) 11 Page - Thurlby Thandar Instruments Ltd. |
|
|
|||||||||||||||||||||||||||||
1908 데이터시트(HTML) 11 Page - Thurlby Thandar Instruments Ltd. |
|
11 / 14 page ![]() MEASUREMENT RESULT BUFFER Contents (each entry) Index, Primary Measurement, Secondary Measurement, Date, Time (1 second resolution). .CSV file contents Index Active Mode Output state Measurement results (V and A) Calculated results (R and W) System Date System Time Measurement Timestamp Sequence Mode Step and Iteration Length Maximum of 100000 entries, FIFO style. DIGITAL INPUT/OUTPUT (DIO) Signals 5 user definable signal pins, HV interlock (SMU4201 only), Global Trigger In, Global Trigger out (self-resetting based on trigger input), Ground and +5V (fuse limited to 500mA). Voltage Reference Chassis ground referenced. Input Levels Logic zero: -0.25V to +1V (diode clamped to 0V) Logic one: +1.75V to +5.25V (diode clamped to +5V) Output Levels Logic zero: open-drain MOS, typically 0.2ohm, 100mA maximum sink. Logic one: nominally 4.7kohm pull-up to +5V Logic Active High / Low global port selection. REMOTE CONTROL INTERFACES LAN Ethernet 100/10 base-T hardware connection. LXI Conformance 1.5 LXI Device Specification 2016. USB Standard USB 2.0 hardware connection. Operates as a virtual COM port. GPIB (optional) Conforming with IEEE488.1 and IEEE488.2 Remote Command Processing Time Typically < 5ms between receiving the command terminator for an output change at the instrument and the output beginning to change. SYSTEM SPEEDS Measure to Memory Up to 5k/s sustained. ENVIRONMENTAL Operating Range +5°C to +40°C, 20% to 80% RH non-condensing. Operating Mains 220V-240V or 110V-120V AC ±10%, 50/60Hz, by internal selection; 150VA maximum demand. Installation Category II. Environmental Indoor use at altitudes up to 2000m, Pollution Degree 2. Storage Range -20°C to +60°C, 10% to 90% RH non-condensing. EMC EN61326-1 and EN61326-2-1, group 1, class A. Safety EN61010-1 and EN61010-2-030 (uncategorized measurements). MAIN and SENSE terminals rated for voltages up to 210V to ground and between terminals. Front panel CHASSIS terminal intended for ground reference purposes only. Security Kensington security slot incorporated. MECHANICAL Size (nominal) Bench Use: 250mm(W) x 97mm(H) x 295mm(D) Rack Mount: 213.5mm(W) (½ rack) x 86.5mm(H) (2U) x 269mm(D) Weight (nominal) 4.25kg |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |