5 / 7 page ![]() FUNCTIONAL DESCRIPTION The L4954 includes a monitoring circuit to warn the microprocessor if a low voltage or no voltage condition is occurring. When the voltage on the STCAP pin drops below 7.5V (typ), the LVW output will go low. This tells the microprocessor to stop executing code and save vital information. The reset output will go low when REG4 (5V-STBY) drops below (VREG4 - 250mV) or 4.75V is minimum value. The RESET output doesn’t go above 0.4V until REG4 has gone back above 4.75V (min). Any spike will tell the microprocessor to start op- erating. Once the STCAP line passes 7.5V (typ), the LVWarn output will also return to high state. The STCAP pin acts like a delay circuit. Due to the large capacitor (470 µF), the STCAP pin al- lows the battery voltage to decay slowly giving the microprocessor time to store data. Also, during short low voltage or negative voltage conditions, the STCAP pin protects the 5V STBY output from dropping below the RESET and LVW trip points. The four outputs are expected to fol- low the battery voltage down to 11V for REG1, 9V for REG2, 6V for REG3 and REG4. The L4954 has a STBY mode to keep the micro- processor and memories alive during an ignition off conditions. The EN1 input pin is controlled by the microprocessor. A high on the EN1 input turns on REG1, REG2, REG3, and HSD1. A Low on EN1 places the part in stand-by mode with REG4 on. The High side driver outputs HSD2 and HSD3 are controlled by EN2 and EN3 respectively: a Low on the control input turns the corresponding high side driver off. ELECTRICAL CHARACTERISTICS (Continued) Symbol Parameter Test Condition Min. Typ. Max. Unit LVWARN OUTPUT THLVW LVW Threshold on STCAP 7.5 V VLVW LVW Output Voltage STCAP <7.5V; VIL = ”0” 0 0.4 V STCAP >7.5V VIH = ”1” 2.75 5 V trise LVW Output Rise Time CLVW = 0.1 µF 3.9 ms tfall LVW Output Fall Time CLVW = 0.1 µF 12.6 µs RESET OUTPUT THRES Reset Threshold on Reg 4 4.5 V VRES Reset Output Voltage Set VS so that VOUT5STBY <4.5V; VIL = ”0” 0 0.4 V Set VS so that VOUT5STBY is not less than normal REG4 output voltage; VIH = ”1” 2.75 5 V trise Reset Output Rise Time CRESET =0.1 µF 4.5 ms tfall Reset Output Fall Time CRESET =0.1 µF37 µs STCAP (V) 0 7.5 7.5 TIME 4.75 4.75 REG4 (V) 5 0 5 0.4 5 LVWarn (V) RESET (V) TIME TIME TIME D95AU349A TIMING DIAGRAM L4954 5/7 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |