| 전자부품 데이터시트 검색엔진 |
|
M29F800AT 데이터시트(PDF) 12 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M29F800AT 데이터시트(HTML) 12 Page - STMicroelectronics |
|
12 / 21 page ![]() M29F800AT, M29F800AB 12/21 Table 10. DC Characteristics (TA = 0 to 70°C, –40 to 85°C or –40 to 125°C) Note: 1. Sampled only, not 100% tested. 2. TA =25 °C, VCC =5V. Symbol Parameter Test Condition Min Typ. (2) Max Unit ILI Input Leakage Current 0V ≤ VIN ≤ VCC ±1 µA ILO Output Leakage Current 0V ≤ VOUT ≤ VCC ±1 µA ICC1 Supply Current (Read) E=VIL,G = VIH, f = 6MHz 10 20 mA ICC2 Supply Current (Standby) TTL E= VIH 1mA ICC3 Supply Current (Standby) CMOS E=VCC ± 0.2V, RP = VCC ± 0.2V 35 150 µA ICC4 (1) Supply Current (Program/Erase) Program/Erase Controller active 20 mA VIL Input Low Voltage –0.5 0.8 V VIH Input High Voltage 2 VCC + 0.5 V VOL Output Low Voltage IOL = 5.8mA 0.45 V VOH Output High Voltage TTL IOH = –2.5mA 2.4 V Output High Voltage CMOS IOH = –100µAVCC –0.4 V VID Identification Voltage 11.5 12.5 V IID Identification Current A9 = VID 100 µA VLKO (1) Program/Erase Lockout Supply Voltage 3.2 4.2 V Alternative Toggle Bit (DQ2). The Alternative Toggle Bit can be used to monitor the Program/ Erase controller during Erase operations. The Al- ternative Toggle Bit is output on DQ2 when the Status Register is read. During Chip Erase and Block Erase operations the Toggle Bit changes from ’0’ to ’1’ to ’0’, etc., with successive Bus Read operations from addresses within the blocks being erased. Once the operation completes the memory returns to Read mode. During Erase Suspend the Alternative Toggle Bit changes from ’0’ to ’1’ to ’0’, etc. with successive Bus Read operations from addresses within the blocks being erased. Bus Read operations to ad- dresses within blocks not being erased will output the memory cell data as if in Read mode. After an Erase operation that causes the Error Bit to be set the Alternative Toggle Bit can be used to identify which block or blocks have caused the er- ror. The Alternative Toggle Bit changes from ’0’ to ’1’ to ’0’, etc. with successive Bus Read Opera- tions from addresses within blocks that have not erased correctly. The Alternative Toggle Bit does not change if the addressed block has erased cor- rectly. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |