| 전자부품 데이터시트 검색엔진 |
|
C8051F310 데이터시트(PDF) 37 Page - Silicon Laboratories |
|
|
|||||||||||||||||||||||||||||
C8051F310 데이터시트(HTML) 37 Page - Silicon Laboratories |
|
37 / 228 page ![]() Rev. 1.7 37 C8051F310/1/2/3/4/5/6/7 Digital Supply Current—CPU Inactive (Idle Mode, not fetching instructions from Flash) IDD (Note 3) VDD = 3.0 V, F = 25 MHz —3.8 4.3 mA VDD = 3.0 V, F = 1 MHz —0.20— mA VDD = 3.0 V, F = 80 kHz —16— µA VDD = 3.6 V, F = 25 MHz —4.8 5.3 mA IDD Supply Sensitivity (Note 3, Note 4) F = 25 MHz —44— %/V F = 1 MHz —56— %/V IDD Frequency Sensitivity (Note 3, Note 6) VDD = 3.0 V, F < 1 MHz, T = 25 °C — 0.21 — mA/MHz VDD = 3.0 V, F > 1 MHz, T = 25 °C — 0.15 — mA/MHz VDD = 3.6 V, F < 1 MHz, T = 25 °C — 0.28 — mA/MHz VDD = 3.6 V, F > 1 MHz, T = 25 °C — 0.19 — mA/MHz Digital Supply Current (Stop Mode, shutdown) Oscillator not running, VDD Monitor Disabled —< 0.1— µA Table 3.1. Global DC Electrical Characteristics (Continued) –40°C to +85°C, 25 MHz System Clock unless otherwise specified. Parameter Conditions Min Typ Max Units Notes: 1. Given in Table 9.1 on page 110. 2. SYSCLK must be at least 32 kHz to enable debugging. 3. Based on device characterization data, not production tested. 4. Active and Inactive IDD at voltages and frequencies other than those specified can be calculated using the IDD Supply Sensitivity. For example, if the VDD is 3.3 V instead of 3.0 V at 25 MHz: IDD = 7.8 mA typical at 3.0 V and f = 25 MHz. From this, IDD = 7.8 mA + 0.67 x (3.3 V – 3.0 V) = 8 mA at 3.3 V and f = 25 MHz. 5. IDD can be estimated for frequencies < 15 MHz by multiplying the frequency of interest by the fre- quency sensitivity number for that range. When using these numbers to estimate IDD for > 15 MHz, the estimate should be the current at 25 MHz minus the difference in current indicated by the fre- quency sensitivity number. For example: VDD = 3.0 V; F = 20 MHz, IDD = 7.8 mA – (25 MHz – 20 MHz) x 0.21 mA/MHz = 6.75 mA. 6. Idle IDD can be estimated for frequencies < 1 MHz by multiplying the frequency of interest by the frequency sensitivity number for that range. When using these numbers to estimate Idle IDD for > 1 MHz, the estimate should be the current at 25 MHz minus the difference in current indicated by the frequency sensitivity number. For example: VDD = 3.0 V; F = 5 MHz, Idle IDD = 4.8 mA – (25 MHz – 5 MHz) x 0.15 mA/MHz = 1.8 mA. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |