Back Button CPR2 Datasheet HTML 4Page - Clarke International CPR2 Datasheet HTML 5Page - Clarke International CPR2 Datasheet HTML 6Page - Clarke International CPR2 Datasheet HTML 7Page - Clarke International CPR2 Datasheet HTML 8Page - Clarke International CPR2 Datasheet HTML 9Page - Clarke International CPR2 Datasheet HTML 10Page - Clarke International CPR2 Datasheet HTML 11Page - Clarke International CPR2 Datasheet HTML 12Page - Clarke International  
Zoom Inzoom in Zoom Outzoom out
 8 / 12 page
background image
8
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Additionally, following prolonged use, the jaws may fail to grip the mandril
effectively, and will therefore need replacing. Dis-assemble the jaw housing
assembly, and re-assemble using genuine parts supplied from your nearest
CLARKE dealer, ensure you carry out the adjustment above.
TROUBLESHOOTING
PERFORMANCE
Please note that factors other than the tool may effect its operation and
efficiency such as reduced compressor output, excessive drain on the airline
moisture or restrictions in the air-line, or the use of connectors of improper size
or poor condition which will reduce air supply.
Grit or gum deposits inside the tool may also reduce its efficiency. This
condition can be corrected by cleaning out the air strainer and flushing out
the tool with gum solvent or oil, or failing this, the motor may require
dismantling.
SYMPTOM
PROBLEM
SOLUTION
Tool runs at normal
speed but slows down
under any load.
1. Excessive pressure on
tip.
2. Motor parts worn.
3. Worn or sticking
mechanism due to
lack of lubricant.
1. Reduce the force
applied
2. Return to Clarke dealer
for repair.
3. Drip air tool lubricating
oil into air inlet. Allow oil
to soak moving parts
before using.
Tool runs slowly. Air flows
weakly from exhaust.
1. Motor parts jammed
with gum/dirt.
2. Regulator in closed
position.
3. General airflow
blocked by dirt.
1. Examine inlet air filter for
cleanliness.
2. Adjust regulator to open
position.
3. Operate tool in short
bursts.
Tool will not run. Air flows
freely from exhaust.
1. Motor vanes stuck
due to buildup of
foreign material.
1. Disconnect air supply
and rotate tool assembly
manually.
2. Try operating tool in
short bursts.
3. Tap motor housing gently
with a rubber mallet.
4. Drip a few drops of air
tool lubricating oil into air
inlet to soak moving
parts.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com