13 / 27 page ![]() ISL81601DEMO2Z 2. Quick Start Guide UG190 Rev.1.00 Page 13 of 27 Oct.16.19 2.3 Separate Test Guides • Disabling the Reverse Function: If there is no charge requirement, and the input terminals (VIN, GND) are connected to the power supply, check Disable the reverse function (see Figure 17). When this button is checked, the input power supply voltage is not related to the input voltage set point and the output terminal should not be connected to any power supply. • Enabling the Frequency Dither Function: When Frequency Dither is required, the Enable pin enables the Frequency Dither function (see Figure 17). . . Figure 16. Input and Output Discharging Waves Figure 17. Disable Reverse Operation and Enable Dither Functions VIN Battery 5V/Div VOUT System 5V/Div When the adapter is removed, the system voltage changes back to the set point, and the battery discharges to the system. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|