| 전자부품 데이터시트 검색엔진 |
|
TSC101 데이터시트(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
TSC101 데이터시트(HTML) 13 Page - STMicroelectronics |
|
13 / 17 page ![]() TSC101 Parameter definitions 13/17 Output voltage accuracy The output voltage accuracy is the difference between the actual output voltage and the theoretical output voltage. Ideally, the current sensing output voltage should be equal to the input differential voltage multiplied by the theoretical gain, as in the following formula: Vout-th=Av . Vsense The actual value is very slightly different, mainly due to the effects of: ● the input offset voltage Vos, ● non-linearity Figure 22. Vout vs. Vsense theoretical and actual characteristics The output voltage accuracy, expressed in percentage, can be calculated with the following formula: with Av=20V/V for TSC101A, Av=50V/V for TSC101B and Av=100V/V for TSC101C. Vout accuracy for Vsense= 10mV Vsense Vout 10mV ideal actual ΔV out abs V out A v V sense ⋅ () – () A v V sense ⋅ -------------------------------------------------------------------------- = |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |