8 / 13 page ![]() Application information STCC08 8/13 3 Application information Figure 5. Application example with an MCU direct drive + ACS The placement of a 100 nF capacitor between VCC and GND close to the STCC08 is advised. SW is an electromechanical switch that is part of the application design, for example, the water sensor in a washing machine. 3.1 Recommendations The STCC08 is designed for 5 and 10 mA ACSs, ACSTs and TRIACs. STCC08 basic application The microcontroller reads the AC switch state from the AVF output of the STCC08. The microcontroller can power-off the application driving a front-end relay. Figure 6. Non-insulated application AVF V CC GND R IG AC IN G POWER SWITCH SIGNAL SHAPING AVF DRIVER GATE DRIVER + - MCU 3.3V to 5V V CC V CC AVF GND LOAD LINE NEUTRAL ACS AVF V CC GND R IG AC IN G POWER SWITCH SIGNAL SHAPING AVF DRIVER GATE DRIVER + - MCU 3.3V to 5V V CC V CC AVF GND LOAD NEUTRAL SAFETY TURN OFF ACS LINE FRONT END RELAY |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|