Back Button STW4102 Datasheet HTML 18Page - STMicroelectronics STW4102 Datasheet HTML 19Page - STMicroelectronics STW4102 Datasheet HTML 20Page - STMicroelectronics STW4102 Datasheet HTML 21Page - STMicroelectronics STW4102 Datasheet HTML 22Page - STMicroelectronics STW4102 Datasheet HTML 23Page - STMicroelectronics STW4102 Datasheet HTML 24Page - STMicroelectronics STW4102 Datasheet HTML 25Page - STMicroelectronics STW4102 Datasheet HTML 26Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 34 page
background image
Battery monitoring
STw4102
22/34
8
Battery monitoring
8.1
Gas gauge
The gas gauge is designed to monitor the battery capacity. A current sensing resistor
(typically of 30 m
Ω) is needed between the negative terminal of the battery and the ground.
The sensing resistor voltage drop is input to a 13-bit integrating AD converter. When a
conversion cycle is completed, depending on the output sign, the result is forwarded to the
charge or discharge 24-bit accumulator, and the number of conversions is incremented in a
12-bit counter.
One accumulator accumulates current flowing into the battery during charging and the other
accumulates discharge current during system operation. The remaining battery charge is
given by the difference between the charge and discharge accumulators.
Figure 23.
Gas gauge block diagram
The Digital Base Band (DBB) can control, enable and read gas gauge data through I2C
control registers. The DBB can read the value of the most recent conversion in two’s
complement format by reading the CONVDATA registers.
The RD_REQ bit enables the transfer of the charge/discharge accumulators and conversion
counter register. The transfer can take up to eight 32 kHz cycles, therefore a delay of
AD converter
12 bits + sign bit
ICG+
ICG-
From 2’s
to binary
Charge
accumulator
Discharge
accumulator
24 bit max
Charge
registers
Discharge
registers
Conv_data
registers
registers
Conv_number
12 bits Counter
EOC
13
24
24
Control logic
sign
cg_enable
cg_calibration
cg_clock
Control
registers
32kHz
Σ



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com