| 전자부품 데이터시트 검색엔진 |
|
TDA9109 데이터시트(PDF) 17 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
TDA9109 데이터시트(HTML) 17 Page - STMicroelectronics |
|
17 / 30 page ![]() I.6 - Sync Identification Status The MCU can read (address read mode : 8D) the status register via the I 2C bus, and then select the sync priority depending on this status. Among other data this register indicates the pres- ence of sync pulses on H/HVIN, VSYNCIN and (when 12V is supplied) whether a Vext has been extracted from H/HVIN. Both horizontal and vertical sync are detected even if only 5V is supplied. In order to choose the right sync priority the MCU may proceed as follows (see I 2C Address Table) : - refresh the status register, - wait at least for 20ms (Max. vertical period), - read this status register. Sync priority choice should be : Vext det H/V det V det Sync priority Subaddress 03 (D8) Comment Sync type No Yes Yes 1 Separated H & V Yes Yes No 0 Composite TTL H&V Of course, when the choice is made, we can refresh the sync detections and verify that the extracted Vsync is present and that no sync type change has occured. The sync processor also gives sync po- larity information. I.7 - IC status The IC can inform the MCU about the 1st horizontal PLL and vertical section status (locked or not) and about the XRAY protection (activated or not). Resetting the XRAY internal latch can be done either by decreasing the VCC or VDD supply or directly resetting it via the I 2C interface. I.8 - Sync Inputs Both H/HVIN and VSYNCIN inputs are TTL com- patible triggers with hysterisis to avoid erratic detection. Both inputs include a pull up resistor connected to VDD. I.9 - Sync Processor Output The sync processor indicates on the HLOCKOUT Pin whether 1st PLL is locked to an incoming horizontal sync. HLOCKOUT is a TTL compatible CMOS output. Its level goes to high when locked. In the same time the D8 bit of the status register is set to 0. This information is mainly used to trigger safety procedures (like reducing B+ value) as soon as a OPERATING DESCRIPTION (continued) Z T Z Figure 5 dd C TRAMEXT Figure 6 change is detected on the incoming sync. Further to this, it may be used in an automatic procedure for free running frequency (f0) adjustment : Sending the desired f0 on the sync input and progressively decreasing the free running fre- quency I 2C register value (address 02), the HLOCKOUT Pin will go high as soon as the proper setting is reached. Setting the free running frequency this way allows to fully exploit the TDA9109/S horizontal frequency range. II - HORIZONTAL PART II.1 - Internal Input Conditions A digital signal (horizontal sync pulse or TTL composite) is sent by the sync processor to the horizontal input. It may be positive or negative (see Figure 5). Using internal integration, both signals are recog- nized if Z/T < 25%. Synchronization occurs on the leading edge of the internal sync signal. The mini- mum value of Z is 0.7 µs. Another integration is able to extract the vertical pulse from composite sync if the duty cycle is higher than 25% (typically d = 35%) (see Figure 6). The last feature performed is the removal of equali- zation pulses to avoid parasitic pulses on the phase comparator (which would be disturbed by missing or extraneous pulses). TDA9109/S 17/30 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |