| 전자부품 데이터시트 검색엔진 |
|
ASD-PL2F 데이터시트(PDF) 2 Page - Gamewell-FCI by Honeywell |
|
|
|||||||||||||||||||||||||||||
ASD-PL2F 데이터시트(HTML) 2 Page - Gamewell-FCI by Honeywell |
|
2 / 2 page ![]() GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0617 Rev. E page 2 of 2 www.gamewell-fci.com Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: •4.0" (10.2 cm) square box •3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box • Single-gang box (except relay or isolator bases) • With B501BH or B501BHT base, use a 4.0" (10.2 cm) square box • With B224RB or B224BI base, use a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. Sensor Spacing Gamewell-FCI recommends spacing sensors in com- pliance with NFPA 72. In low airflow applications with smooth ceilings, space sensors 30 feet (9.1 m). For specific information regarding sensor spacing, place- ment and special applications, refer to NFPA 72. Specifications Size: 2.1” (5.1 cm) high x 4.1” (10.4 cm) diameter installed in B501 base, 6.1” (15.5 cm) diameter installed in ADB-FL base. Shipping Weight: 5.2 oz. (147 g) Operating Temperature: ASD-PL2F: 32° F to 120° F (0° C to 49° C) ASD-PTL2F: 32° F to 100° F (0° C to 38° C) UL®-Listed Velocity Range: 0-4000 ft./min. (1,219.2 m/min.), suitable for installation in ducts. Relative Humidity: 10-93% (non-condensing) Thermal Ratings: Fixed-temperature setpoint 135° F (57° C) Electrical Specifications VoltageRange: 15 – 32 volts DC peak Standby Current: (max. avg.): .0003 A @ 24 VDC (one communication every 5 seconds with LED enabled) Maximum Alarm Current: .0065 A @ 24 VDC (LED) lit). Bases and Options ADB-FL 6.1” (15.5 cm) diameter B501 4.1” (10.4 cm) diameter B501BH or B501BHT Sounder base assembly (B501BHT produces a temporal pattern). Includes B501 base B224RB Relay Base Screw terminals: Up to 14 AWG (2.0 mm2) Relay type: Form-C Rating: 2.0A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2” x 1.2” (15.7 x 3.0 cm) Maximum: 25 devices between isolator bases. RA400Z Remote alarm indicator, LED. BCK-200 Black detector covers (box of 10) |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |