Back Button TLC2932IPWLE Datasheet HTML 14Page - Texas Instruments TLC2932IPWLE Datasheet HTML 15Page - Texas Instruments TLC2932IPWLE Datasheet HTML 16Page - Texas Instruments TLC2932IPWLE Datasheet HTML 17Page - Texas Instruments TLC2932IPWLE Datasheet HTML 18Page - Texas Instruments TLC2932IPWLE Datasheet HTML 19Page - Texas Instruments TLC2932IPWLE Datasheet HTML 20Page - Texas Instruments TLC2932IPWLE Datasheet HTML 21Page - Texas Instruments TLC2932IPWLE Datasheet HTML 22Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 24 page
background image
TLC2932
HIGH-PERFORMANCE PHASE-LOCKED LOOP
SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997
18
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
APPLICATION INFORMATION
Using the low-pass filter in Figure 25(b) and divider ratio N, the transfer function for phase and frequency are
shown in equations 1 and 2. Note that the transfer function for phase differs from the transfer function for
frequency by only the divider value N. The difference arises from the fact that the feedback for phase is unity
while the feedback for frequency is 1/N.
Hence, transfer function of Figure 24 (a) for phase is
F2(s)
F1(s) +
Kp
@ KV
N
@ (T1 ) T2)
1
) s
@ T2
s2
) s 1 )
Kp
@KV @T2
N
@(T1)T2)
)
Kp
@K
V
N
@(T1)T2)
(1)
and the transfer function for frequency is
F
OUT(s)
F
REF(s)
+
Kp
@ KV
(T1
) T2)
1
) s
@ T2
s2
) s
@ 1 )
Kp
@K
V
@T2
N
@(T1)T2)
)
Kp
@KV
N
@(T1)T2)
(2)
The standard two-pole denominator is D = s2 + 2
ζ ωn s + ωn2 and comparing the coefficients of the denominator
of equation 1 and 2 with the standard two-pole denominator gives the following results.
wn +
Kp
@ KV
N
@ (T1 ) T2)
Solving for T1 + T2
T1
) T2 +
Kp
@ KV
N
@ w 2
n
(3)
and by using this value for T1 + T2 in equation 3 the damping factor is
z +
wn
2 @
T2
)
N
Kp
@ K
V
solving for T2
T2
+
2
z
w –
N
Kp
@ K
V
then by substituting for T2 in equation 3
T1
+
K
V
@ Kp
N
@ w 2
n
–
2
z
w
n
)
N
Kp
@ K
V



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com