| 전자부품 데이터시트 검색엔진 |
|
SW-442 데이터시트(PDF) 2 Page - M/A-COM Technology Solutions, Inc. |
|
|
|||||||||||||||||||||||||||||
SW-442 데이터시트(HTML) 2 Page - M/A-COM Technology Solutions, Inc. |
|
2 / 4 page ![]() • North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macomtech.com for additional data sheets and product information. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. 2 GaAs SPDT Terminated Switch DC - 3.0 GHz Rev. V4 SW-442 ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is considering for development. Performance is based on target specifications, simulated results, and/or prototype measurements. Commitment to develop is not guaranteed. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is not guaranteed. Electrical Specifications: TA = 25°C, Z0 = 50 Ω 3, VCTL = -3V (unless otherwise specified) 3. External DC blocking capacitors are required on all RF ports when using positive voltage control. 4. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 1 GHz, 39 pF for 0.5 GHz - 3 GHz. Parameter Test Conditions Units Min. Typ. Max. Insertion Loss 4 DC-1 GHz 1-2 GHz 2-3 GHz dB dB dB — — — 0.5 0.8 1.1 0.7 1.0 1.25 Isolation DC-1 GHz 1-2 GHz 2-3 GHz dB dB dB 36 25 21 38 28 22 — — — VSWR DC-2 GHz 2-3 GHz Ratio Ratio — — 1.4:1 1.6:1 1.5:1 1.7:1 P1dB (2.7 V supply) 500 MHz - 3 GHz dBm — 24 — P1dB (5 V supply) 500 MHz - 3 GHz dBm — 28 — IP2 (2.7 V supply) 2-Tone 900 MHz, 5 MHz spacing, 10 dBm each tone dBm — 80 — IP3 (2.7 V supply) 2-Tone 900 MHz, 5 MHz spacing, 10 dBm each tone dBm — 50 — Trise, Tfall Ton, Toff Transients 10% to 90% RF, 90% to 10% RF 50% Control to 90% RF, 50% Control to 10% RF In-Band nS nS mV — — — 40 60 10 — — — Control Current VCTL = -3V µA — 6 15 Truth Table Mode (Control) V1 V2 RFC - RF1 RFC - RF2 Positive 7 0 + 0.2 V +2.5 to +8 V +2.5 to +8 V 0 + 0.2 V On Off Off On Negative 8 0 + 0.2 V -2.5 to -8 V -2.5 to -8 V 0 + 0.2 V Off On On Off 7. External DC blocking capacitors are required on all RF ports and GND. GND capacitors can be used with positive control voltage to resonate lead inductance for improved isolation. 8. If negative control is used, DC blocking capacitors and GND capacitors are not required. Absolute Maximum Ratings 5,6 Parameter Absolute Maximum Input Power (0.5 - 3.0 GHz) 3 V Control 5 V Control +30 dBm +33 dBm Operating Voltage +8.5 Volts Operating Temperature -40°C to +85°C Storage Temperature -65°C to +150°C 5. Exceeding any one or combination of these limits may cause permanent damage to this device. 6. M/A-COM does not recommend sustained operation near these survivability limits. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |