33 / 62 page ![]() © 2009 Microchip Technology Inc. DS22153B-page 33 MCP98243 5.2.3.1 Comparator Mode Comparator mode is selected using bit 0 of CONFIG. In this mode, the Event output is asserted as active-high or active-low using bit 1 of CONFIG. Figure 5-13 shows the conditions that toggle the Event output. If the device enters Shutdown mode with asserted Event output, the output will de-assert. It will remain de- asserted until the device enters Continuous Conver- sion mode and after the first temperature conversion is completed, tCONV. After the initial temperature conver- sion, TA must satisfy the TUPPER or TLOWER boundary conditions in order for Event output to be asserted. Comparator mode is useful for thermostat-type applications, such as turning on a cooling fan or triggering a system shutdown when the temperature exceeds a safe operating range. 5.2.3.2 Interrupt Mode In the Interrupt mode, the Event output is asserted as active-high or active-low (depending on the polarity configuration) when TA drifts above or below TUPPER and TLOWER limits. The output is deasserted by setting bit 5 (Interrupt Clear) of CONFIG. If the device enters Shutdown mode with asserted Event output, the output will de-assert. It will remain de-asserted until the device enters Continuous Conversion mode and after the first temperature conversion is completed, tCONV. After the initial temperature conversion, TA must cross the TUPPER or TLOWER boundary conditions in order for Event output to be asserted. In addition, if TA >= TCRIT the Event output is forced as Comparator mode and asserts until TA < TCRIT - THYST. While the Event output is asserted, user must send Clear Interrupt command (bit 5 of CONFIG) for Event output to de-assert, when temperature drops below the critical limit, TA < TCRIT - THYST. Otherwise, Event output remains asserted (see Figure 5-13 for graphical descrip- tion). Switching from Interrupt mode to Comparator mode also de-asserts Event output. This mode is designed for interrupt driven microcontroller based systems. The microcontroller receiving the interrupt will have to acknowledge the interrupt by setting bit 5 of CONFIG register from the MCP98243. 5.2.4 TEMPERATURE RESOLUTION The MCP98243 is capable of providing a temperature data with 0.5°C to 0.0625°C resolution. The Resolution can selected using the Resolution register (Register 5- 8) which is located in address ‘00001000’b. This address location is not specified in JEDEC Standard JC42.4. However, it provides additional flexibility while being functionally compatible with JC42.4 and provide a 0.25°C resolution at 125 ms (max.). The selected resolution can be read by user using bit 4 and bit 3 of the Capability register (Register 5-2). A 0.25°C resolution is set as POR default by factory. TABLE 5-2: TEMPERATURE CONVERSION TIME Resolution tCONV (ms) Samples/sec (typical) 0.5°C 30 33 0.25°C (Power-up default) 65 15 0.125°C 130 8 0.0625°C 260 4 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |