4 / 13 page ![]() RE46C140 CMOS Photoelectric Smoke Detector ASIC with Interconnect R&E International and Timer Mode A Subsidiary of Microchip Technology Inc. Product Specification 2009 © Microchip Technology Inc. DS22179A-page 4 AC Electrical Characteristics at TA =-25° to 75°, VDD=9V, VSS=0V, Component Values from Figure 2 ; R9=100KΩ, R12=10MΩ, C5= 1.5nF(unless otherwise noted) Limits Parameter Symbol Test Pin Test Conditions Min Typ Max Units Oscillator Period TPOSC 12 No Alarm Condition 9.4 10.5 11.5 mS LED and STROBE On Time TON1 11,4 Operating 9.4 10.5 11.5 mS TPLED1 11 Standby, No Alarm 39 43 47 S TPLED2 11 Local Alarm Condition .45 .5 .55 S TPLED3 11 Timer Mode, No Local Alarm 9.6 10.75 11.8 S LED Period TPLED4 11 Remote Alarm Only LED IS NOT ON S TPER1 4,6 Standby, No Alarm 9.6 10.75 11.8 S TPER1A 4,6 Standby, After 1 Valid Smoke Sample 1.8 2 2.2 S TPER1B 4,6 Standby, After 2 Consecutive Valid Smoke Samples .9 1 1.1 S TPER2 4,6 In Local Alarm – (3 Consecutive Valid Smoke Samples) .9 1 1.1 S TPER3 4,6 In Remote Alarm 7.2 8 8.9 S TPER4 4,6 Pushbutton Test 300 336 370 mS STROBE and IRED Pulse Period TPER5 4,6 Chamber Test or Low Battery Test, no Alarms 38.9 47.1 S IRED On Time TON2 6 Operating 94 104 115 uS THON1 8,9 Operating, Alarm Condition, Note 1 450 500 550 mS Horn On Time THON2 8,9 Low Battery or Failed Chamber Test , No Alarm 9.5 10.5 11.5 mS THOF1 8,9 Operating, Alarm Condition, Note 1 450 500 550 mS THOF2 8,9 Operating, Alarm Condition, Note 1 1.35 1.5 1.65 S Horn Off Time THOF3 8,9 Low Battery or Failed Chamber Test, No Alarm 39 43 47 S IO Charge Dump Duration TIODMP 7 At Conclusion of Local Alarm or Test Alarm .9 1.46 S IO Delay TIODLY1 7 From Start of Local Alarm to IO Active 0 S IO Filter TIOFILT 7 IO pulse width guaranteed to be filtered. IO as Input, No Local Alarm 600 mS Remote Alarm Delay TIODLY2 7 No Local Alarm, From IO Active Horn Active 1.05 2.0 S Timer Period TTPER No Alarm Condition, Note 2 8 10 12 Min Note 1 – See timing diagram for Horn Temporal Pattern Note 2 – During the timer mode the LED Period is 10.5 seconds. The LED period will return to a 43 seconds at the conclusion of the timer mode. Note 3 - TPOSC and TON2 are 100% production tested. All other timing is guaranteed by functional testing. Typical values are for design information and are not guaranteed. Limits over the specified temperature range are not production tested and are based on characterization data. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |