8 / 27 page ![]() SE95_7 © NXP B.V. 2009. All rights reserved. Product data sheet Rev. 07 — 2 September 2009 8 of 27 NXP Semiconductors SE95 Ultra high accuracy digital temperature sensor and thermal watchdog false alert if the address 0Ch is sent and cannot be active on the I2C-bus if this address is used. Consider using the SE98 since it supports SMBus ARA as well as time-out features and provides ±1 °C accuracy. 8.2 Register list The SE95 contains 7 data registers. The registers can be 1 byte or 2 bytes wide, and are defined in Table 5. The registers are accessed by the value in the content of the pointer register during I2C-bus communication. The types of registers are: read only, read/write, and reserved for manufacturer use. Note that when reading a two-byte register, the host must provide enough clock pulses as required by the I2C-bus protocol (see Section 8.7) for the device to completely return both data bytes. Otherwise the device may hold the SDA line in LOW state, resulting in a bus hang condition. 8.3 Register pointer The register pointer or pointer byte is an 8-bit data byte that is equivalent to the register command in the I2C-bus definitions and is used to identify the device register to be accessed for a write or read operation. Its values are listed as pointer values in Table 5. For the device register I2C-bus communication, the pointer byte may or may not need to be included within the command as illustrated in the I2C-bus protocol figures in Section 8.7. The command statements for writing data to a register must always include the pointer byte; while the command statements for reading data from a register may or may not include it. To read a register that is different from the one that has been recently read, the pointer byte must be included. However, to re-read a register that has been recently read, the pointer byte may not have to be included in the reading. Table 4. Address table MSB LSB 1001 A2 A1 A0 Table 5. Register table Register name Pointer value R/W POR state Description Conf 01h R/W 00h configuration register: contains a single 8-bit data byte; to set an operating condition Temp 00h read only N/A temperature register: contains two 8-bit data bytes; to store the measured Temp Tos 03h R/W 5000h overtemperature shutdown threshold register: contains two 8-bit data bytes; to store the overtemperature shutdown limit; default Tos =80 °C Thyst 02h R/W 4B00h hysteresis register: contains two 8-bit data bytes; to store the hysteresis limit; bit 7 to bit 0 are also used in OTP (One Time Programmable) test mode to supply OTP write data; default Thyst =75 °C ID 05h read only A1h identification register: contains a single 8-bit data byte for the manufacturer ID code Reserved 04h N/A N/A reserved Reserved 06h N/A N/A reserved |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |