| 전자부품 데이터시트 검색엔진 |
|
AT25DF321 데이터시트(PDF) 13 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
AT25DF321 데이터시트(HTML) 13 Page - ATMEL Corporation |
|
13 / 37 page ![]() 13 3669B–DFLASH–6/09 AT25DF321 9.2 Write Disable The Write Disable command is used to reset the Write Enable Latch (WEL) bit in the Status Reg- ister to the logical “0” state. With the WEL bit reset, all program, erase, Protect Sector, Unprotect Sector, and Write Status Register commands will not be executed. The Write Disable command is also used to exit the Sequential Program Mode. Other conditions can also cause the WEL bit to be reset; for more details, refer to the WEL bit section of the Status Register description on page 21. To issue the Write Disable command, the CS pin must first be asserted and the opcode of 04h must be clocked into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the WEL bit in the Status Register will be reset to a logical “0”. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and the state of the WEL bit will not change. Figure 9-2. Write Disable 9.3 Protect Sector Every physical sector of the device has a corresponding single-bit Sector Protection Register that is used to control the software protection of a sector. Upon device power-up or after a device reset, each Sector Protection Register will default to the logical “1” state indicating that all sectors are protected and cannot be programmed or erased. Issuing the Protect Sector command to a particular sector address will set the corresponding Sector Protection Register to the logical “1” state. The following table outlines the two states of the Sector Protection Registers. Before the Protect Sector command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a logical “1”. To issue the Protect Sector command, the CS pin must first be asserted and the opcode of 36h must be clocked into the device followed by three address bytes designating any address within the sector to be locked. Any additional data clocked into the device will be ignored. When the CS pin is deas- serted, the Sector Protection Register corresponding to the physical sector addressed by A23- SCK CS SI SO MSB 23 1 0 00000100 67 5 4 OPCODE HIGH-IMPEDANCE Table 9-1. Sector Protection Register Values Value Sector Protection Status 0 Sector is unprotected and can be programmed and erased. 1 Sector is protected and cannot be programmed or erased. This is the default state. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |