Back Button ST7522 Datasheet HTML 17Page - Sitronix Technology Co., Ltd. ST7522 Datasheet HTML 18Page - Sitronix Technology Co., Ltd. ST7522 Datasheet HTML 19Page - Sitronix Technology Co., Ltd. ST7522 Datasheet HTML 20Page - Sitronix Technology Co., Ltd. ST7522 Datasheet HTML 21Page - Sitronix Technology Co., Ltd. ST7522 Datasheet HTML 22Page - Sitronix Technology Co., Ltd. ST7522 Datasheet HTML 23Page - Sitronix Technology Co., Ltd. ST7522 Datasheet HTML 24Page - Sitronix Technology Co., Ltd. ST7522 Datasheet HTML 25Page - Sitronix Technology Co., Ltd. Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 45 page
background image
ST7522
Ver 1.0c
21/45
2002/07/10
Set Column Address
This command specifies a column address of the display data RAM. When the display data RAM is accessed by the MPU
continuously, the column address is incremented by I each time it is accessed from the set address. Therefore, the MPU
can access to data continuously. The column address stops to be incremented at address 95, and the page address is not
changed continuously.
A0
RD
―
WR
―
D7
D6
D5
D4
D3
D2
D1
D0
0
1
0
0
0
0
0
A3
A2
A1
A0
A0
RD
―
WR
―
D7
D6
D5
D4
D3
D2
D1
D0
0
1
0
0
0
0
1
A7
A6
A5
A4
This command loads the column address register.
A7
A6
A5
A4
A3
A2
A1
A0
Column Address
0
0
0
0
0
0
0
0
0(default)
0
0
0
0
0
0
0
1
1
.
.
.
.
.
.
.
.
0
1
0
1
1
1
1
1
95
Read Status
A0
RD
―
WR
―
D7
D6
D5
D4
D3
D2
D1
D0
0
0
1
0
ADC
ON/OFF RESET
0
0
0
0
Reading the command I/O register (A0=0) yields system status information.
The ADC bit indicates the way column addresses are assigned to segment drivers.
ADC=1 : Normal. Column address n = segment driver n.
ADC=0: Inverted. Column address 95-n = segment driver n.
The ON/OFF bit indicates the current status of the display.
It is the inverse of the polarity of the display ON/OFF command.
ON/OFF=1: Display OFF
ON/OFF=0: Display ON
The RESET bit indicates whether the driver is executing a hardware or software reset or if it is in normal operating mode,
RESET=1: Currently executing reset command.
RESET=0: Normal operation
Low column set
High column set



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com