| 전자부품 데이터시트 검색엔진 |
|
AS5043ASST 데이터시트(PDF) 26 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS5043ASST 데이터시트(HTML) 26 Page - ams AG |
|
26 / 36 page ![]() AS5043 Data Sheet – Angular Output Tolerances www.austriamicrosystems.com Revision 1.80 26 – 36 s rpm n μ 384 60 ⋅ = for slow mode In practice, there is no upper speed limit. The only restriction is that there will be fewer samples per revolution as the speed increases. Regardless of the rotational speed, the absolute angular value is always sampled at the highest resolution. Table 6: Speed Performance Fast Mode (Pin Mode = 1) Slow Mode (Pin Mode = 0 or open) 610rpm = 1024 samples / turn 610rpm = 256 samples / turn 1220rpm = 512 samples / turn 1220rpm = 128 samples / turn 2441rpm = 256 samples / turn 2441rpm = 64 samples / turn etc… etc… 18.5 Output Delays The propagation delay is the delay between the time that the sample is taken until it is available as angular data. This delay is 96µs in fast mode (pin Mode = high) and 384µs in slow mode (pin Mode = low or open). The analog output produces no further delay, the output voltage will be updated as soon as it is available. Using the SSI interface for data transmission, an additional delay must be considered, caused by the asynchronous sampling (0….1/fsample) and the time it takes the external control unit to read and process the angular data from the AS5043. 18.5.1 Angular Error Caused by Propagation Delay A rotating magnet will cause an angular error caused by the propagation delay. This error increases linearly with speed: delay pr rpm e sampling . 6 (deg) ∗ ∗ = where esampling = angular error [°] rpm = rotating speed [rpm] prop.delay = propagation delay [seconds] Note: since the propagation delay is known, it can be automatically compensated by the control unit processing the data from the AS5043. 18.6 Internal Timing Tolerance The AS5043 does not require an external ceramic resonator or quartz. All internal clock timings for the AS5043 are generated by an on-chip RC oscillator. This oscillator is factory trimmed to ±5% accuracy at room temperature (±10% over full temperature range). This tolerance influences the ADC sampling rate: 18.6.1 Absolute Output; SSI Interface A new angular value is updated every 96µs +/- 5% (Mode = 1) or 384µs +/- 5% (Mode = 0 or open) |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |