7 / 13 page ![]() X24321 7 Acknowledge Polling The maximum write cycle time can be significantly reduced using Acknowledge Polling. To initiate Acknowledge Polling, the master issues a start condi- tion followed by the Slave Address Byte for a write or read operation. If the device is still busy with the nonvolatile write cycle, then no ACK will be returned. If the device has completed the nonvolatile write opera- tion, an ACK will be returned and the host can then proceed with the read or write operation. Refer to figure 6. BYTE LOAD COMPLETED BY ISSUING STOP. ENTER ACK POLLING ISSUE START ISSUE SLAVE ADDRESS BYTE (READ OR PROGRAM) ACK RETURNED? NONVOLATILE WRITE CYCLE COMPLETE. CONTINUE SEQUENCE? CONTINUE NORMAL READ OR PROGRAM COMMAND SEQUENCE PROCEED ISSUE STOP NO YES YES ISSUE STOP NO 7040 FM 09 READ OPERATIONS Read operations are initiated in the same manner as write operations with the exception that the R/W bit of the Slave Address Byte is set to one. There are three basic read operations: Current Address Reads, Random Reads, and Sequential Reads. Current Address Read Internally, the device contains an address counter that maintains the address of the last byte read or written, incremented by one. After a read operation from the last address in the array, the counter will “roll over” to the first address in the array. After a write operation to the last address in a given page, the counter will “roll over” to the first address of the same page. Upon receipt of the Slave Address Byte with the R/W bit set to one, the device issues an acknowledge and then transmits the byte at the current address. The master terminates the read operation when it does not respond with an acknowledge during the ninth clock and then issues a stop condition. Refer to figure 7 for the address, acknowledge, and data transfer sequence. It should be noted that the ninth clock cycle of the read operation is not a “don’t care.” To terminate a read operation, the master must either issue a stop condi- tion during the ninth cycle or hold SDA HIGH during the ninth clock cycle and then issue a stop condition. FROM THE S T A R T SLAVE ADDRESS S T O P A C K DATA SIGNALS FROM THE MASTER SDA BUS SIGNALS SLAVE 1 S P 0 1 0 1 7040 FM 10 Figure 6. Acknowledge Polling Sequence Figure 7. Current Address Read Sequence |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |