6 / 10 page ![]() X9511 6 A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.) 3067 FRM T07.3 AUTOSTORE Cycle Timing Diagram Notes: VASTH – AUTOSTORE threshold voltage VASEND – AUTOSTORE cycle end voltage tASTO – AUTOSTORE cycle time (6) Typical values are for TA = 25°C and nominal supply voltage. (7) This parameter is periodically sampled and not 100% tested. Symbol Parameter Limits Units Min. Typ.(6) Max. tGAP Time Between Two Separate Push Button Events 0 µs tDB Debounce Time 30 60 ms tS SLOW After Debounce to Wiper Change on a Slow Mode 100 250 375 ms tS FAST (7) Wiper Change on a Fast Mode 25 50 75 ms tPU (7) Power Up to Wiper Stable 500 µs tR VCC (7) VCC Power-up Rate 0.2 50 mV/ µs tASTO (7) AUTOSTORE Cycle Time 2 ms VASTH (7) AUTOSTORE Threshold Voltage 4 V VASEND (7) AUTOSTORE Cycle End Voltage 3.5 V 3067 ILL F04.2 5 AUTOSTORE CYCLE IN PROGRESS VASTH VASEND tASTO V CC STORE TIME TIME (ms) |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|