2 / 14 page ![]() MP3V5004G Sensors 2 Freescale Semiconductor Pressure Operating Characteristics Table 1. Operating Characteristics (VS = 3.0 Vdc, TA = 25°C unless otherwise noted, P1 > P2. Characteristic Symbol Min Typ Max Unit Pressure Range POP 0 — 3.92 400 kPa mm H2O Supply Voltage(1) 1. Device is ratiometric within this specified excitation range. VS 2.7 3.0 3.3 VDC Supply Current IS — — 10 mAdc Span at 306 mm H2O (3 kPa) (2) 2. Span is defined as the algebraic difference between the output voltage at specified pressure and the output voltage at the minimum rated pressure. VFSS — 1.8 — V Offset(3) (4) 3. Offset (Voff) is defined as the output voltage at the minimum rated pressure. 4. Accuracy (error budget) consists of the following: Linearity: Output deviation from a straight line relationship with pressure over the specified pressure range. Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and from the minimum or maximum operating temperature points, with zero differential pressure applied. Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or maximum rated pressure, at 25 °C. Offset Stability: Output deviation, after 1000 temperature cycles, -30 ° to 100°C, and 1.5 million pressure cycles, with minimum rated pressure applied. TcSpan: Output deviation over the temperature range of 10 ° to 60°C, relative to 25°C. TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 10 ° to 60°C, relative to 25°C. Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of VFSS, at 25°C. VOFF 0.45 0.6 0.75 V Sensitivity V/P — 0.6 5.9 — V/kPa mV/mm H2O Accuracy(4) (5) 0 to 100 mm H2O (10 to 60°C) 100 to 400 mm H2O (10 to 60°C) 5. Auto-Zero at Factory Installation: Due to the sensitivity of the MP3V5004G, external mechanical stresses and mounting position can affect the zero pressure output reading. Auto-zeroing is defined as storing the zero pressure output reading and subtracting this from the device's output during normal operations. Reference AN1636 for specific information. The specified accuracy assumes a maximum temperature change of ±5 °C between auto-zero and measurement. — — — — — — ±1.5 ±2.5 %VFSS %VFSS |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |