| 전자부품 데이터시트 검색엔진 |
|
ADS1258IPHPREP 데이터시트(PDF) 35 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
ADS1258IPHPREP 데이터시트(HTML) 35 Page - Texas Instruments |
|
35 / 57 page ![]() 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CS SCLK DIN Command Byte Register Data(1) Register Data(1)(2) (1) One or more bytes depending on MUL bit. (2) After the prescribed number of registers are read, then one or more additional commands can be issued in succession. NOTE: 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CS SCLK DIN Command 1 Command 2(1) Command 3(1) NOTE: (1) One or more commands can be issued in succession. ADS1258-EP www.ti.com SBAS445C – MARCH 2009 – REVISED DECEMBER 2009 Register Read Command Beginning with the eighth SCLK rising edge (command byte completed), the MSB of the data is To read register data, the first three bits of the shifted in. The remaining seven SCLK rising edges command byte to be shifted into the device are 010. complete the write to a single register. If MUL = '1', These bits are followed by the multiple register read the data to the next register can be written by bit (MUL). If MUL = '1', then multiple registers can be supplying additional SCLKs. The operation terminates read in sequence beyond the desired register. If when the last register is accessed (address = 09h), MUL = '0', only data from the addressed register can as shown in Figure 60. be read. The last four bits of the command word are the beginning register address bits. During this time, CONTROL COMMANDS the invalid data may appear on DOUT until the command is completed. This data should be ignored. Pulse Convert Command Beginning with the eighth falling edge of SCLK (command byte completed), the MSB of the register (See Conversion Control section) data is output on DOUT. The remaining eight SCLK transitions complete the read of a single register. If Reset Command MUL = '1', the data from the next register can be read The Reset command resets the ADC. All registers in sequence by supplying additional SCLKs. The are reset to their default values. A conversion in operation terminates when the last register is process continues but is invalid when completed accessed (address = 09h); see Figure 59. (DRDY low). This conversion data should be discarded. Note that the SPI interface may require Register Write Command reset for this command, or any command, to function. To write register data, the first three bits of the To ensure device reset under a possible locked SPI command byte to be shifted into the device are 011. interface condition, do one of the following: 1) toggle These bits are followed by the multiple register read CS high then low and send the reset command; or 2) bit (MUL). If MUL = '1', then multiple registers can be hold SCLK inactive for 256/fCLK or 4096/fCLK and send written in sequence beyond the desired register. If the reset command. The control commands are MUL = '0', only data to the addressed register can be illustrated in Figure 61. written. The remaining four bits of the command word are the beginning register address bits. During this time, the invalid data may appear on DOUT until the command is completed. This data should be ignored. Figure 60. Register Write Operation Figure 61. Control Command Operation Copyright © 2009, Texas Instruments Incorporated Submit Documentation Feedback 35 Product Folder Link(s): ADS1258-EP |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |