| 전자부품 데이터시트 검색엔진 |
|
E5GN-R101T-FLK 데이터시트(PDF) 5 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5GN-R101T-FLK 데이터시트(HTML) 5 Page - Omron Electronics LLC |
|
5 / 17 page ![]() E5GN 5 Models with Analog Inputs Models with One Control Output and a 100 to 240-VAC Power Supply Note: Models with analog inputs do not display the temperature unit. *1. If heating/cooling control mode is used, an auxiliary output is used as a control output for the cooling side. The number of auxiliary outputs that can be used will decrease by one. Also, the signal for the control output for the cooling side will be a relay output. *2. A current control output can be used as the transfer output. In that case, an auxiliary output is used as the control output. (This is not possible for models without an auxiliary output.) The control output will be a relay output. The number of auxiliary outputs that can be used will decrease by one. Models with One Control Output and a 24-VAC/VDC Power Supply *1. If heating/cooling control mode is used, an auxiliary output is used as a control output for the cooling side. The number of auxiliary outputs that can be used will decrease by one. Also, the signal for the control output for the cooling side will be a relay output. *2. A current control output can be used as the transfer output. In that case, an auxiliary output is used as the control output. (This is not possible for models without an auxiliary output.) The control output will be a relay output. The number of auxiliary outputs that can be used will decrease by one. Case color Control output Control mode *1 No. of auxiliary outputs Detection of heater burnout, SSR failure, and heater overcurrent No. of event inputs Transfer output *2 Communi- cations Previous model New model Thermocou- ple input Resistance thermome- ter input Black Relay output Standard or heating/ cooling 1 --- --- --- RS-485 --- --- E5GN- R103L-FLK Voltage output (for driving SSR) --- --- E5GN- Q103L-FLK Current output Transfer output using control output --- --- --- E5GN-C1L Case color Control output Control mode *1 No. of auxiliary outputs Detection of heater burnout, SSR failure, and heater overcurrent No. of event inputs Transfer output *2 Communi- cations Previous model New model Thermocou- ple input Resistance thermome- ter input Black Relay output Standard or heating/ cooling 1 --- --- --- RS-485 --- --- E5GN- R103LD-FLK Voltage output (for driving SSR) --- --- E5GN -Q103LD-FLK Current output Transfer output using control output --- --- --- E5GN-C1LD |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |