10 / 14 page ![]() SA9203/5 sames 10/14 INT This active high output (default after reset) operates as follows: When disabled (via A6), INT remains reset. On either the rising or trailing edge of STB (programmable via D6 of Port B-F direction control register), INT is set. INT remains set until Port A (or any bit of PORT A if in bit- addressing mode) is read by the microprocessor at which point INT is reset, remaining so until the next active edge of STB. (See figure 14 for timing diagram). The output polarity of INT is programmed via D7 of the Port B- F dirction control register (See Figure 11). RST This active low reset signal resets the contents of all registers to zero. Sets all ports to input mode and the bi-directional data/address bus to input. A valid RST signal is specified as an active low pulse of 100ns minimum duration. CS The active low CS signal is internally latched by the trailing edge of ALE. TIMING DIAGRAMS FIGURE 12: µP Read Waveforms RDE t t t RD DR-01270 LL LC t ALE CS AD -8/A AL t 08 LA t AD t ADDRESS RDF t t RD t CC LD RV t CL t DATA VALID |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|