Back Button SA9605ASA Datasheet HTML 4Page - Sames SA9605ASA Datasheet HTML 5Page - Sames SA9605ASA Datasheet HTML 6Page - Sames SA9605ASA Datasheet HTML 7Page - Sames SA9605ASA Datasheet HTML 8Page - Sames SA9605ASA Datasheet HTML 9Page - Sames SA9605ASA Datasheet HTML 10Page - Sames SA9605ASA Datasheet HTML 11Page - Sames SA9605ASA Datasheet HTML 12Page - Sames Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 14 page
background image
SA9605A
sames
8/14
The frequencies shown in the above table were chosen to allow a 4 - 3 - 2 scaling ratio
for rated conditions. This facility provides ease of interface with applications which use
the same post divider with mechanical counter or unchanged microcontroller software
for different current rated kWh meters.
For example, a meter manufacturer may wish to build meters for 3 system configurations
with rated current loading of 80A
RMS, 60ARMS and 40ARMS.
The rated line voltage is
230V
RMS.
FOUT1 Frequency
Consider the case where FOUT1 is the output of the energy counting block. For each
of the three rated conditions, the input current sensing resistors are chosen to ensure that
16µA
RMS flows into the current sensing pins.
Case 1
I
L = 80ARMS
1 pulse on FOUT1 =
80 * 230 * 3 = 47.6Ws
1160
Case 2
I
L = 60ARMS
1 pulse on FOUT1 =
60 * 230 * 3 = 35.7Ws
1160
Case 3
I
L = 40ARMS
1 pulse on FOUT1 =
40 * 230 * 3 = 23.8Ws
1160
The amount of energy represented by one pulse for each of the three cases is different.
In addition to changing the current sensing resistor network, the energy counting block
must also be altered.
FOUT2 Frequency
Now consider the advantage of the user selectable frequency available on FOUT2.
Again the input current sensing resistors must be chosen to ensure that 16µA
RMS flows
into the current sensing pins.
Case 1
I
L = 80ARMS,
PGM1 = 0
PGM0 = 0
1 pulse on FOUT2 =
80 * 230 * 3 = 10.8kWs
5.11
Case 2
I
L = 60ARMS,
PGM1 = 0
PGM0 = 1
1 pulse on FOUT2 =
60 * 230 * 3 = 10.8kWs
3.83
Case 3
I
L = 40ARMS,
PGM1 = 1
PGM0 = 0
1 pulse on FOUT2 =
40 * 230 * 3 = 10.8kWs
2.55



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com