9 / 34 page ![]() STMPS2141, STMPS2151, STMPS2161, STMPS2171 Functional description Doc ID 13793 Rev 4 9/34 3 Functional description 3.1 Fault blanking The STMPS devices feature a 10 ms fault blanking. Fault blanking allows current-limit faults, including momentary short-circuit faults that occur when hot-swapping a capacitive load, and also ensures that no fault is issued during power-up. When a load transient causes the device to enter current limit, an internal counter starts. If the load fault persists beyond the 10 ms fault-blanking timeout, the FAULT output asserts “low”. Load-transient faults less than 10 ms (typ.) do not cause a FAULT output assertion. Only current-limit faults are blanked. Die over-temperature faults and input voltage drops below the UVLO threshold cause an immediate fault output. 3.2 Overcurrent/over-temperature protection In overcurrent or short-circuit condition, the switch limits the current at a value of about 120% of the rated current. If the temperature of the die goes above the limit value, the switch turns off. 3.3 FAULT conditions In power switch applications, 4 types of FAULT conditions are common. These fault conditions and the response of the STMPS21x1 power switches are described in the following Table 3. Table 3. FAULT conditions Fault Condition STMPS21x1 action Short circuit Output shorted to GND via resistance path of < 1 Ω, causing a rapid current surge. Reduces output voltage to reduce the current. Asserts FAULT pin after a blanking period Over-current Output connected to a load that sinks current above threshold. Reduces output voltage to reduce the current. Asserts FAULT pin after a blanking period. Overheating Temperature of junction exceeds 135°C due to any reason. Turn OFF output until temperature falls below 125°C. Asserts FAULT pin immediately. Undervoltage Input voltage drops below the UVLO treshold. Turn OFF output until input voltage rises above the UVLO treshold plus hysteresis. Asserts FAULT pin immediately. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |