21 / 36 page ![]() TLE4998S3C Signal Processing Data Sheet 21 Rev 1.1, 2009-09 6.5 Clamping The clamping function is useful for separating the output range into an operating range and error ranges. If the magnetic field is exceeding the selected measurement range, the output value OUT is limited to the clamping values. Any value in the error range is interpreted as an error by the sensor counterpart. The clamping values are calculated by: Clamping value low (deactivated if CL=0): Clamping value high (deactivated if CH=127): Table 12 Clamping Parameter Symbol Limit Values Unit Notes min. max. Register size CL,CH 2 x 7 bit (0...127) Clamping value low OUTCL 0 65024 LSB16 1) 1) For CL = 0 and CH = 127, the clamping function is disabled Clamping value high OUTCH 511 65535 LSB16 1) 2) 2) OUT CL < OUTCH mandatory Clamping quantization steps ∆OUT Cx 512 LSB16 3) 3) Quantization starts for CL at 0 LSB 16 and for CH at 65535 LSB16 OUT CL CL 32 16 ⋅⋅ = OUT CH CH 1 + () 32 16 1 – ⋅⋅ = |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|