  MPXC12DT1 Datasheet HTML 1Page - Freescale Semiconductor, Inc MPXC12DT1 Datasheet HTML 2Page - Freescale Semiconductor, Inc MPXC12DT1 Datasheet HTML 3Page - Freescale Semiconductor, Inc MPXC12DT1 Datasheet HTML 4Page - Freescale Semiconductor, Inc MPXC12DT1 Datasheet HTML 5Page - Freescale Semiconductor, Inc  
Zoom Inzoom in Zoom Outzoom out
 2 / 5 page
background image
MPXC12DT1
Sensors
2
Freescale Semiconductor
Pressure
Freescale Semiconductor's Bio-compatible Pressure
Sensors have been designed for medical usage by
combining the performance of Freescale Semiconductor's
shear stress pressure sensor design and the use of
biomedically approved materials. Materials with a proven
history in medical situations have been chosen to provide a
sensor that can be used with confidence in applications, such
as invasive blood pressure monitoring. It can be sterilized
using ethylene oxide. The portions of the pressure sensor
that are required to be biomedically approved are the rigid
housing and the gel coating.
The rigid housing is molded from a white, medical grade
polysulfone that has passed extensive biological testing
including: 10993-5:1999, 10993-10:2002, and 10993-
11:1993.
These sensors contain a silicone dielectric gel which
covers the silicon piezoresistive sensing element. The gel is
a nontoxic, nonallergenic elastomer system which meets all
USP XX Biological Testing Class V requirements. The
properties of the gel allow it to transmit pressure uniformly to
the diaphragm surface, while isolating the internal electrical
connections from the corrosive effects of fluids, such as
saline solution. The gel provides electrical isolation sufficient
to withstand defibrillation testing, as specified in the proposed
Association for the Advancement of Medical Instrumentation
(AAMI) Standard for blood pressure transducers. A
biomedically approved opaque filler in the gel prevents bright
operating room lights from affecting the performance of the
sensor.
The MPXC12DT1 is a no-gel option.



Html Pages

1 2 3 4 5


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com