Back Button F1206A0R20FSTR Datasheet HTML 15Page - AVX Corporation F1206A0R20FSTR Datasheet HTML 16Page - AVX Corporation F1206A0R20FSTR Datasheet HTML 17Page - AVX Corporation F1206A0R20FSTR Datasheet HTML 18Page - AVX Corporation F1206A0R20FSTR Datasheet HTML 19Page - AVX Corporation F1206A0R20FSTR Datasheet HTML 20Page - AVX Corporation F1206A0R20FSTR Datasheet HTML 21Page - AVX Corporation F1206A0R20FSTR Datasheet HTML 22Page - AVX Corporation F1206A0R20FSTR Datasheet HTML 23Page - AVX Corporation  
Zoom Inzoom in Zoom Outzoom out
 21 / 23 page
background image
Fig. 6b. Choice of 0.75A fuse, example #6.
Pre-arcing I2t
Maximum I2t design rule
I2t for sample switch-on pulse
Fig. 5b. Choice of fuse, example #5.
Pre-arcing I2t
Maximum I2t design rule
I2t for sample switch-on pulse
Accu-Guard®
SMD Thin-Film Fuse
6. Switch-on pulse and steady-state current
In Figure 6a, the switch-on pulse is a triangle pulse with a
5.1 x 10-3 A2sec Joule integral of 5 msec duration; the 0.75A
fuse will meet this requirement, see Figure 6b.
5. Complex current pulse
If the pulse consists of several waveforms, all of them should
be evaluated separately, and then the total Joule integral
should be calculated as well.
2 msec/div
0.5A/div
Fig. 6a. Switch-on pulse and steady-state current,
example #6.
200
μsec/div
2A/div
Fig. 5a. Complex pulse, example #5.
0.75A
PRE-ARCING TIME l2t, A2 sec
PRE-ARCING TIME, sec
100
10
1
10-1
10-2
10-3
10-4
10-5
10-7
10-6
10-5
10-4
10-3
10-2
10-1
110
x x
X
FUSE PRE-ARCING JOULE INTEGRALS
vs. PRE-ARCING TIME
The
Joule
integral
for
the
second
triangle
is
[(5.33A)2 x 269 x 10-6sec]/3 = 2.55 x 10-3 A2sec, and
0.75A fuse is suitable for this case also, see Figure 5b.
However, for the whole pulse, the Joule integral is
4.7 x 10-3 A2sec, and the total duration is 563 μsec. For the
0.75A fuse, the Joule integral is only 8.6 x 10-3 A2sec for this
pulse duration, so the 1A fuse should be chosen for this
application, see Figure 5b.
In Figure 5a, the Joule integral for the first triangle is
[(4.67A)2 x 294 x 10-6sec]/3=2.14 x 10-3 A2sec
and 0.75A fuse should meet this condition, see Figure 5b.
FUSE PRE-ARCING JOULE INTEGRALS
vs. PRE-ARCING TIME
0.75A
PRE-ARCING TIME l2t, A2 sec
PRE-ARCING TIME, sec
100
10
1
10-1
10-2
10-3
10-4
10-5
10-7
10-6
10-5
10-4
10-3
10-2
10-1
110
x
X
The steady-state current is 0.5A, and 1A fuse is typically rec-
ommended to meet the steady-state condition. Based on
steady-state current, the 1A fuse should be chosen for this
application.
DESIGNING FOR CURRENT PULSE SITUATIONS (CONT.)
34



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com