13 / 17 page ![]() Lineage Power 13 Data Sheet October 14, 2009 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W NH020-Series Power SIPs: Figure 32. NH020F Power Dissipation vs. Output Current. With the known heat dissipation and a given local ambient temperature, the minimum airflow can be chosen from the derating curves in Figure 33. Figure 33. Power Derating vs. Local Ambient Temperature and Air Velocity . For example, if the unit dissipates 2.0 W of heat, the mini- mum airflow in an 80 °C environment is 1.0 m/s (200 ft./min.). Keep in mind that these derating curves are approximations of the ambient temperatures and airflows required to keep the power SIP temperature below its maximum rating. Once the SIP is assembled in the actual system, the SIP’s temper- ature should be checked as shown in Figure 28 to ensure it does not exceed 115 °C. Layout Considerations Copper paths must not be routed between pins 2 and 3 and pins 7 and 8. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|