8 / 11 page ![]() OLED Display Module 96RGBx96 (1.10”) OLED Display YOS3C sales@greatecs.com www.greatecs.com 8 FUNCTION SPECIFICATION 1. Commands Refer to the Technical Manual for the SEPS114A 2. Power Down and Power up Sequence To protect OEL panel and extend the panel life time, the driver IC power up/down routine should include a delay period between high voltage and low voltage power sources during turn on/off. It gives the OEL panel enough time to complete the action of charge and discharge before/after the operation. 2.1. Power up Sequence 1. Power up VDD & VDDIO 2. Send Display off command 3. Initialization 4. Clear Screen 5. Power up VCC_C 6. Delay 100ms (when VCC_C is stable) 7. Send Display on command 2.2. Power down Sequence 1. Send Display off command 2. Power down Vcc_c 3. Delay 100ms (when Vcc_c is reach 0 and panel is completely discharges) 4. Power down V |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|