19 / 25 page ![]() KP236 Analog Absolute Pressure Sensor Specification Data Sheet 19 Revision 1.0, 2010-06-21 3.3 Operating Range The following operating conditions must not be exceeded in order to ensure correct operation of the device. All parameters specified in the following sections refer to these operating conditions, unless noted otherwise. Table 7 Operating Range Parameter Symbol Values Unit Note / Test Condition Number Min. Typ. Max. Supply voltage V DD 4.5 5.0 5.5 V V OUT is ratiometric to V DD 2.1 Output current on V OUT pin I OUT – -1 – – 1 – mA mA pull-down resistor used pull-up resistor used 2.2 Operating temperature T a -40 – 125 °C 2.3 Ambient operating pressure range p amb 40 – 115 kPa 2.4 Lifetime 1) 1) The life time shall be considered as anticipation with regard to the product that shall not extend the agreed warranty period. t live 15 – – years 2.5 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|