| 전자부품 데이터시트 검색엔진 |
|
815222302 데이터시트(PDF) 5 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
815222302 데이터시트(HTML) 5 Page - Magnetrol International, Inc. |
|
5 / 28 page ![]() 50-605 Kotron RF Point Model 80/81 Level Switches 2 2.0 Installation Caution: Please read the entire installation section carefully prior to starting installation. 2.1 Unpacking Unpack the instrument carefully. Make sure all compo- nents have been removed from the packing material. Inspect all components for damage. Report any concealed damage to the carrier within 24 hours. Check the contents against the packing slip and report any discrepancies to the factory. Check the nameplate model number to be sure it agrees with the packing slip and purchase order. Check and record the serial number for future reference when ordering parts. 2.2 Installation Location Kotron RF Point Level Switches should be located for easy access for service, calibration and monitoring. Switches should not be exposed to ambient temperatures below -40° F (-40° C) or above +160° F (+71° C). Special pre- caution should be made to prevent exposure to corrosive atmosphere, excessive vibration, shock or physical damage. It is common practice to use the metal tank wall as the reference electrode. In such cases, it is required that the probe housing makes a good electrical connection to the tank wall. If there is any doubt about this connection due to the use of PTFE thread tape, gaskets, paint, rust, or any other reason, a separate strap should be installed between the probe housing and the tank. Caution: This unit contains CMOS electronics which may be damaged by static electricity. Do not touch any semi- conductor devices unless you are properly grounded. 2.2.1 Metal Walled Tanks On water-based liquids, there should be no problem with sensitivity or linearity. With non-conductive, low dielectric media, sensitivity can be enhanced by locating the probe close to and parallel with the tank wall. If this is not prac- tical, a concentric ground tube surrounding the probe, sometimes called a stilling well, may be a solution. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |