Back Button DAC712PLG4 Datasheet HTML 11Page - Texas Instruments DAC712PLG4 Datasheet HTML 12Page - Texas Instruments DAC712PLG4 Datasheet HTML 13Page - Texas Instruments DAC712PLG4 Datasheet HTML 14Page - Texas Instruments DAC712PLG4 Datasheet HTML 15Page - Texas Instruments DAC712PLG4 Datasheet HTML 16Page - Texas Instruments DAC712PLG4 Datasheet HTML 17Page - Texas Instruments DAC712PLG4 Datasheet HTML 18Page - Texas Instruments DAC712PLG4 Datasheet HTML 19Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 23 page
background image
LOAD CONNECTIONS
R
1
Sense
Output
R
L
R
2
R
3
AlternateGround
SenseConnection
SystemGround
ACOM
DCOM
Bus
Interface
DAC712
Analog
Power
Supply
0.01 F
m
(1)
0.01 F
m
To+V
CC
To V
-
CC
V
OUT
10kW
10kW
V
REF
DAC712
www.ti.com ................................................................................................................................................. SBAS023A – SEPTEMBER 2000 – REVISED JULY 2009
In some applications it is impractical to return the load
to the ACOM pin of the D/A converter. Sensing the
Because the reference point for VOUT and VREF OUT is
output voltage at the SYSTEM GROUND point is
the ACOM pin, it is important to connect the D/A
reasonable, because there is no change in the
converter load directly to the ACOM pin; see
DAC712 ACOM current, provided that R3 is a
Figure 12.
low-resistance ground plane or conductor. In this
case,
DCOM
may
be
connected
to
SYSTEM
Lead and contact resistances are represented by R1
GROUND as well.
through R3. As long as the load resistance RL is
constant, R1 simply introduces a gain error and can
be removed by gain adjustment of the D/A converter
or system-wide gain calibration. R2 is part of RL if the
output voltage is sensed at ACOM.
(1) Locate close to the DAC712 package.
Figure 12. System Ground Considerations for High-Resolution D/A Converters
Copyright © 2000–2009, Texas Instruments Incorporated
Submit Documentation Feedback
15
Product Folder Link(s): DAC712



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com