전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

SS360ST 데이터시트(PDF) 2 Page - Honeywell Accelerometers

부품명 SS360ST
상세설명  High Sensitivity Bipolar Latching
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  HONEYWELL-ACC [Honeywell Accelerometers]
홈페이지  http://www.inertialsensor.com
Logo HONEYWELL-ACC - Honeywell Accelerometers

SS360ST 데이터시트(HTML) 2 Page - Honeywell Accelerometers

  SS360ST Datasheet HTML 1Page - Honeywell Accelerometers SS360ST Datasheet HTML 2Page - Honeywell Accelerometers SS360ST Datasheet HTML 3Page - Honeywell Accelerometers SS360ST Datasheet HTML 4Page - Honeywell Accelerometers SS360ST Datasheet HTML 5Page - Honeywell Accelerometers  
Zoom Inzoom in Zoom Outzoom out
 2 / 5 page
background image
SS360NT/SS360ST/SS460S
2
www.honeywell.com/sensing
POTENTIAL APPLICATIONS
Industrial/Commercial
Brushless dc motor commutation
Flow-rate sensing for appliances
Speed and RPM sensing
Tachometer, counter pickup
Motor and fan control
Robotics control
Transportation
Speed and RPM sensing
Tachometer, counter pickup
Motor and fan control
Electronic window lift
Convertible roof position
Medical
Medical equipment using electric motors
Table 1. SS360NT/SS360ST/SS460S Performance Specifications (At 3 Vdc to 24 Vdc supply, 20 mA load, TA = -40 ºC to
150 ºC [-40 ºF to 302 ºF] except where otherwise specified.)
Characteristic
Condition
Min.
Typ.
Max.
Unit
Supply voltage
-40 °C to 150 °C [-40 °F to 302 °F]
3
–
24
Vdc
Supply current
Vsupply = 3 V at 25 °C [77 °F]
–
–
–
3.5
–
6
8
mA
Vsat
Gauss >55
–
–
0.6
V
Output leakage current
Gauss >55
–
–
10
µA
Rise/fall time
Vsupply = 12 V at 25 °C [77 °F]
–
–
1.5
µs
Thermal resistance:
SS460S (flat TO-92-style)
SS360NT/SS360ST (SOT-23)
–
–
–
233
303
–
–
°C/W
Operate
-40 °C to 125 °C [-40 °F to 257 °F]
5
30
55
Gauss
Release
-40 °C to 125 °C [-40 °F to 257 °F]
-55
-30
-5
Gauss
Differential
-40 °C to 125 °C [-40 °F to 257 °F]
40
60
80
Gauss
Operating temperature
Vsupply = 3 Vdc to 24 Vdc
-40 [-40]
–
150 [302]
°C [°F]
Storage temperature
–
-40 [-40]
–
165 [329]
°C [°F]
NOTICE
Bipolar Hall-effect sensor ICs may have an initial output in either the ON or OFF state if powered up with an applied magnetic
field in the differential zone (applied magnetic field >Brp and <Bop). Honeywell recommends allowing 10 µs for output voltage to
stabilize after supply voltage has reached its final rated value.
NOTICE
The magnetic field strength (Gauss) required to cause the switch to change state (operate
and release) will be as specified in the magnetic characteristics. To test the switch against
the specified magnetic characteristics, the switch must be placed in a uniform magnetic
field.
Table 2. SS360NT/SS360ST/SS460S Absolute Maximum Ratings
1
Characteristic
Min.
Typ.
Max.
Unit
Supply voltage
-26.0
–
26.0
V
Applied output voltage
-0.5
–
26.0
V
Output current
–
–
20
mA
Magnetic flux
–
–
no limit
Gauss
Note 1:
Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the
electrical and mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions)
are approached, nor will the device necessarily operate at absolute maximum ratings.



Html Pages

1 2 3 4 5


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com