| 전자부품 데이터시트 검색엔진 |
|
AS3668 데이터시트(PDF) 15 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3668 데이터시트(HTML) 15 Page - ams AG |
|
15 / 60 page ![]() www.austriamicrosystems.com/AS3668 Revision 1.11 15 - 60 AS3668 Data Sheet - D e t a i l e d D e s c r i p t i o n 8.1.1 Charge Pump Mode Switching If automatic mode switching is enabled the charge pump monitors the current sources, which are directly connected to the output of the charge pump VCP. In order to identify the enabled current sources, the related registers should be setup before starting the charge pump. If any of the voltage on these current sources drops below the threshold (Vcurr_source), the higher mode is selected after the debounce time (tdeb). The charge pump mode switching supports only a mode change to a higher charge pump mode (e.g.: mode 1:1 to mode 1:2). In case VBAT increases again during operation the automatic mode switching will not change the operation mode from 1:2 down to 1:1. In order to change the mode all current sources must be switched off to reset the charge pump mode switching mechanism. After enabling the current sources again the mode switching mechanism chooses the appropriate mode for the optimized operation of the charge pump either in 1:1 mode or 1:2 mode. In case an automatic pattern is used the current sources get a reset after each pattern cycle because the current sources are automatically switched off when executing a pattern after each cycle. Figure 23. Charge Pump Mode Switching . 8.1.2 Soft Start An implemented soft start mechanism reduces the inrush current. Battery current is smoothed when switching the charge pump on and also at each switching condition. This precaution reduces electromagnetic radiation significantly. 8.1.3 Unused Charge Pump If the charge pump is not used, capacitors CFLY and CVCPOUT can be removed. The pins CP, CN and VCP should be left open and keep register cp_on and cp_auto_on at 0 (default value). Rcp1_1 Effective Charge Pump Output Resistance (Open Loop, fclk = 1MHz) 1:1 Mode; VBAT = 3.6V 2.5 Ω Rcp1_2 1:2 Mode; VBAT = 3V 20 fclk Accuracy Accuracy of Clock Frequency -10 10 % Vcurr_source LED1 - CURR4 current source dropout voltage If the voltage drops below this threshold, the charge pump will use the next available mode (1:1 -> 1:2) 0.2 V Isoft_start Current limit for soft start feature 400 mA tdeb CP automatic up- switching debounce time cp_start_debounce=0 32 ms cp_start_debounce=1 200 s Table 6. Charge Pump Characteristics Symbol Parameter Condition Min Typ Max Unit |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |