17 / 19 page ![]() PWM DC Motor Regulator – Data Sheet AS8410 Rev. 1.0, December 2000 page 17 of 19 For all detected failures an adequate failure handling procedure is integrated to fully protect the motor regulator module. This failure procedures works without interaction of the controlling µP and so the AS8410 can also be used to develop regulator modules without µP. Nevertheless the most important failures are reported in operating mode 1 (OM1) by pull down the set value input pin IN with a current source (3 mA … 10 mA). 4.1.8.1 Motor Failures The principle of the load circuit (motor and power FET) failure detection and handling procedures is the following: a) Motor failure detection principle: The motor current at the high side of the motor and the average value of the motor voltage is permanently measured. In this way the actual motor working point is monitored and permanently compared with the normal motor characteristic. This comparison delivers then the different motor or power FET failures. b) Failure handling procedures: After the detection of any motor or power FET failure, the control of the motor is taken by internal settings (no longer by the input set value IN) to protect the whole system. After a predefined time the AS8410 restarts the control by the input set value again and monitors the motor and power FET. This procedure is repeated up the failure disappears (or the controlling µP is executing a protection reaction by itself). The main internal setting values and reactions of the different load circuit failures in OM1 are listed here below: 1. Over current or short circuit of the motor Handling: a) switch off the motor immediately (delay < 1 µs) b) report of the failure at the pin IN c) check the failure condition again after a waiting time d) reuse the input set value, if the over current condition is over 2. No load of the motor Handling: a) report of the failure at the pin IN b) internal setting of the set value to 75 % c) reuse the input set value, if the no load condition is over 3. Open wire (motor or power FET line) Handling: a) report of the failure at the pin IN b) internal setting of the set value to 75 % c) reuse the input set value, if the open wire condition is over 4. Short-circuited power switch (power FET) Handling: a) report of the failure at the pin IN b) internal setting of the set value to 75 % c) reuse the input set value, if the short-circuit condition is over 5. Mechanically blocked motor Handling: a) report of the failure at the pin IN b) pull down the motor c) check the failure condition again after a waiting time d) reuse the input set value, if the blocked motor condition is over |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |