| 전자부품 데이터시트 검색엔진 |
|
L9952XP 데이터시트(PDF) 27 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9952XP 데이터시트(HTML) 27 Page - STMicroelectronics |
|
27 / 68 page ![]() L9952GXP Protection and diagnosis Doc ID 13518 Rev 5 27/68 3.4 High side driver outputs The component provides a total of 4 high side outputs Out1...4, (7 Ω typ. @ 25C) to drive e.g. LED' s or hall sensors and 1 high side output OUT_HS with 1 Ω typ. @ 25 C). The high side outputs are protected against ● Over- and under voltage ● Overload (short circuit) ● Over temperature with pre warning If the output current exceeds the current shutdown threshold the output transistor is turned off and the corresponding diagnosis bit of the output is set. The switches are automatically disabled in case of reset condition, Vs-under, Vs-over voltage or thermal shutdown (TSD1&2). For OUT_HS an auto recovery feature is available in active mode. If the OUT_HS output current exceeds the current shutdown threshold, the output transistor is turned off and the corresponding diagnosis bit of the output is set. Via SPI command the auto recovery feature can be enabled in order to restart the driver in case of over current shutdown. This over current recovery feature is intended for loads which have an initial current higher than the over current limit of the output (e.g. Inrush current of cold light bulbs). The device itself can not distinguish between a real overload and a non linear load like a light bulb. A real overload condition can only be qualified by time. As an example, the micro controller can switch on light bulbs by setting the over current recovery bit for the first 50ms. After clearing the recovery bit, the output will be automatically disabled if the overload condition still exists. The status of all high side outputs (over-current, open load) can be monitored by SPI interface. In case of a watchdog failure, the high side drivers are switched off. The control bits are not cleared, i.e. the drivers will go to the previous state once the watchdog failure condition disappears. ESD structures are configured for nominal currents only. If external loads are connected to different grounds, the current load must be limited to this nominal current. Note: Loss of ground or ground shift with externally grounded loads. 3.5 Low side driver outputs Rel1, Rel2 The outputs provide an active output zener clamping feature for the demagnetisation of the relay coil, even though a load dump condition exists. For safety reasons the relay drivers are linked with the Watchdog: in case of failure, or missing trigger signal the relay drivers will switch off. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |