7 / 8 page ![]() Evaluation Board User Guide UG-054 Rev. 0 | Page 7 of 8 When these steps are completed, the voltage source can be turned on. If J1 is inserted (connecting EN to VIN for auto- matic startup), the regulator powers up. GROUND CURRENT CONSUMPTION Ground current measurements can determine how much current the internal circuits of the regulator consume while the circuits perform the regulation function. To be efficient, the regulator must consume as little current as possible. Typically, the regulator uses the maximum current when supplying its largest load level (150 mA). Figure 12 shows the typical ground current consump- tion for various load levels at VOUT = 3.3 V and TA = 25°C. When the device is disabled (EN = GND), ground current drops to less than 1 μA. 250 200 150 100 50 0 3.5 5.5 5.3 5.1 4.9 4.7 4.5 4.3 4.1 3.9 3.7 VIN (V) IOUT = 0.1mA IOUT = 1mA IOUT = 10mA IOUT = 50mA IOUT = 100mA IOUT = 150mA Figure 12. Ground Current vs. Input Voltage (VIN) at VOUT = 3.3 V, TA = 25°C |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|