전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

TVS 데이터시트(PDF) 2 Page - Vishay Siliconix

부품명 TVS
상세설명  Transient Voltage Suppressors (TVS) for Automotive Electronic Protection
PDF  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  VISHAY [Vishay Siliconix]
홈페이지  http://www.vishay.com
Logo VISHAY - Vishay Siliconix

TVS 데이터시트(HTML) 2 Page - Vishay Siliconix

  TVS Datasheet HTML 1Page - Vishay Siliconix TVS Datasheet HTML 2Page - Vishay Siliconix TVS Datasheet HTML 3Page - Vishay Siliconix TVS Datasheet HTML 4Page - Vishay Siliconix  
Zoom Inzoom in Zoom Outzoom out
 2 / 4 page
background image
Transient Voltage Suppressors (TVS) for
Automotive Electronic Protection
www.vishay.com
For technical questions within your region, please contact one of the following:
Document Number: 88490
2
DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
Revision: 09-Aug-10
Application Note
Vishay General Semiconductor
Fig. 3 - Parameters of Voltage and Current
PRIMARY PROTECTION OF THE AUTOMOTIVE POWER LINE (LOAD DUMP)
Automotive electronics, such as electronic control units,
sensors, and entertainment systems, are connected to one
power line. The power sources for these electronics are the
battery and alternator, both of which have unstable output
voltages that are subject to temperature, operating status,
and other conditions. Additionally, ESD, spike noise, and
several kinds of transient and surge voltages are introduced
into the power and signal line from automotive systems that
use solenoid loads, such as fuel injection, valve, motor,
electrical, and hydrolytic controllers.
Fig. 4 - Typical Vehicle Power Bus
What is Load Dump?
The worst instances of surge voltage are generated when
the battery is disconnected when the engine is in operation,
and the alternator is supplying current to the power line of
the vehicle. This condition is known as “load dump”, and
most vehicle manufacturers and industry associations
specify a maximum voltage, line impedance, and time
duration for this load dump status, as shown in Figure 5.
Fig. 5 - Output Voltage of Alternator in Load Dump Condition
Two well-known tests simulate this condition: the U.S.’s
ISO-7637-2 pulse 5 and Japan’s JASO A-1 for 14 V
powertrains and JASO D-1 for 27 V powertrains. In this
section we review the application of TVS for load dump in
14 V powertrains.
Specification and Results of Load Dump Tests
The U.S.’s ISO-7637-2 pulse 5 and Japan’s JASO A-1 tests
for 14 V powertrains are simulated in Table 1.
Reverse
Voltage
I
F
V
F
I
R
I
PP
V
WM
V
BR
V
C
Reverse
Current
Forward
Voltage
Forward
Current
A
TCU
ECU
Air-Bag
ABS
Car-Audio
& ......
Battery
Regulator
ESD or Lightning
High Voltage induced
by Alternator
Reaction Transient
from Motor and Spark Plugs
A
Load
X
Output Voltage of Alternator
Battery
Connected
Battery
Disconnected
V
P
V
N
TABLE 1 - MAJOR LOAD DUMP TEST CONDITIONS FOR 14 V POWERTRAINS
V TOTAL (VP)
(V)
VS
(V)
VA
(V)
Ri
(
Ω)
TIME
(ms)
CYCLE TIME
JASO A-1
70
-
12.0
0.8
200
1
88
-
12.0
1.0
200
1
ISO 7637-2 pulse 5
78.5 to 100.5
65 to 87
13.5
0.5 to 4.0
400
1



Html Pages

1 2 3 4


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com