| 전자부품 데이터시트 검색엔진 |
|
PIC18F242 데이터시트(PDF) 233 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC18F242 데이터시트(HTML) 233 Page - Microchip Technology |
|
233 / 332 page ![]() © 2006 Microchip Technology Inc. DS39564C-page 231 PIC18FXX2 DECFSZ Decrement f, skip if 0 Syntax: [ label ] DECFSZ f [,d [,a]] Operands: 0 ≤ f ≤ 255 d ∈ [0,1] a ∈ [0,1] Operation: (f) – 1 → dest, skip if result = 0 Status Affected: None Encoding: 0010 11da ffff ffff Description: The contents of register 'f' are dec- remented. If 'd' is 0, the result is placed in W. If 'd' is 1, the result is placed back in register 'f' (default). If the result is 0, the next instruc- tion, which is already fetched, is discarded, and a NOP is executed instead, making it a two-cycle instruction. If ’a’ is 0, the Access Bank will be selected, overriding the BSR value. If ’a’ = 1, then the bank will be selected as per the BSR value (default). Words: 1 Cycles: 1(2) Note: 3 cycles if skip and followed by a 2-word instruction. Q Cycle Activity: Q1 Q2 Q3 Q4 Decode Read register 'f' Process Data Write to destination If skip: Q1 Q2 Q3 Q4 No operation No operation No operation No operation If skip and followed by 2-word instruction: Q1 Q2 Q3 Q4 No operation No operation No operation No operation No operation No operation No operation No operation Example: HERE DECFSZ CNT, 1, 1 GOTO LOOP CONTINUE Before Instruction PC = Address (HERE) After Instruction CNT = CNT - 1 If CNT = 0; PC = Address (CONTINUE) If CNT ≠ 0; PC = Address (HERE+2) DCFSNZ Decrement f, skip if not 0 Syntax: [ label ] DCFSNZ f [,d [,a] Operands: 0 ≤ f ≤ 255 d ∈ [0,1] a ∈ [0,1] Operation: (f) – 1 → dest, skip if result ≠ 0 Status Affected: None Encoding: 0100 11da ffff ffff Description: The contents of register 'f' are dec- remented. If 'd' is 0, the result is placed in W. If 'd' is 1, the result is placed back in register 'f' (default). If the result is not 0, the next instruction, which is already fetched, is discarded, and a NOP is executed instead, making it a two- cycle instruction. If ’a’ is 0, the Access Bank will be selected, overriding the BSR value. If ’a’ = 1, then the bank will be selected as per the BSR value (default). Words: 1 Cycles: 1(2) Note: 3 cycles if skip and followed by a 2-word instruction. Q Cycle Activity: Q1 Q2 Q3 Q4 Decode Read register 'f' Process Data Write to destination If skip: Q1 Q2 Q3 Q4 No operation No operation No operation No operation If skip and followed by 2-word instruction: Q1 Q2 Q3 Q4 No operation No operation No operation No operation No operation No operation No operation No operation Example: HERE DCFSNZ TEMP, 1, 0 ZERO : NZERO : Before Instruction TEMP = ? After Instruction TEMP = TEMP - 1, If TEMP = 0; PC = Address (ZERO) If TEMP ≠ 0; PC = Address (NZERO) |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |