| 전자부품 데이터시트 검색엔진 |
|
AS8510 데이터시트(PDF) 22 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8510 데이터시트(HTML) 22 Page - ams AG |
|
22 / 47 page ![]() www.ams.com/AS8510 Revision 3.5 21 - 46 AS8510 Datasheet - Detailed Descr i p ti on 7.4.4 Standby Mode2 (SBM2) Standby Mode 2 is an extension of the Standby Mode1 to achieve even a lower power in the data acquisition system by providing interrupt to the microcontroller only when the data sample exceeds the set current threshold. The Standby Mode can be entered only through the STOP state. Transition to SBM2 mode occurs when the “START BIT” D0 of Mode Control register MOD_CTL_REG in Table 33 is set to “1” and Mode Control Bits D7,D6 to “1,1” through SPI. In this mode the date rate is programmable with the time of Ta in the Ta control registers B, C. The data sample is made available and an interrupt signal is generated on INT pin only when the input signal exceeds the threshold set in Current Threshold Registers D,E. It should be noted here that the data is stable for Ta secs. The functionality is illustrated in Figure 8. Figure 8. Standby Mode 2 7.5 Reference-Voltage Band gap-reference voltage is used for the ADC as a reference and for the generation of the current for external temperature measurement. 7.6 Oscillators A High-speed oscillator (HS) generates the oversampling clock. For internal state machine and Interrupt generation, a low-speed Oscillator (LS) is also available. 7.7 Power-On Reset The AS8510 has PORs, APOR and DPOR on analog and digital power supplies respectively. On PORs of both supplies, initialization sequence happens and the system status is shown in state diagram (see Figure 4). As shown in the state diagram, the system is in RESET state until DPOR output goes to logic HIGH and subsequently until APOR output goes to logic HIGH. Once analog power supply is available, the system goes into OTP_INT state and loads the default values into the control and data registers and goes into STOP state. If analog POR, APOR goes low at any time, the system goes into RESET state. In the STOP state, the AS8510 can be programmed and by giving start command it starts working following the state machine. ADC t Tconv Start SBM2 Ta sec. Ta sec. Ta sec. IDD I Tconv Tconv I MCU |I| > I Threshold INT Channel DATA Register DATA – A1 DATA – A0 DATA – A2 DATA – A3 TINT |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |