21 / 165 page ![]() User’s Manual 15 2.3.1 Running Dynamic C via Serial Programming Cable Dynamic C uses the serial port on your PC that you specified during installation. If you are using a USB port to connect your computer to the RCM3365/RCM3375 module, choose Options > Project Options and select “Use USB to Serial Converter” on the Communications tab. 2.3.1.1 Run a Sample Program Use the File menu to open the sample program PONG.C, which is in the Dynamic C SAMPLES folder. Press function key F9 to compile and run the program. The STDIO window will open on your PC and will display a small square bouncing around in a box. This program shows that the CPU is working. The sample program described in Section 6.5, “Run the PINGME.C Sample Program,” tests the TCP/IP portion of the board. 2.3.1.2 Troubleshooting If Dynamic C cannot find the target system (error message "No Rabbit Processor Detected." ): • Check that the RCM3365/RCM3375 is powered correctly — the red CORE LED on the Prototyping Board should be lit when the RCM3365/RCM3375 is mounted on the Prototyping Board and the AC adapter is plugged in . • Check both ends of the programming cable to ensure that they are firmly plugged into the PC and the PROG connector, not the DIAG connector, is plugged in to the program- ming port on the RCM3365/RCM3375 with the marked (colored) edge of the program- ming cable towards pin 1 of the programming header. • Ensure that the RCM3365/RCM3375 module is firmly and correctly installed in its connectors on the Prototyping Board. • Dynamic C uses the COM port specified during installation. Select a different COM port within Dynamic C. From the Options menu, select Project Options, then select Communications . Select another COM port from the list, then click OK. Press <Ctrl-Y> to force Dynamic C to recompile the BIOS. If Dynamic C still reports it is unable to locate the target system, repeat the above steps until you locate the COM port used by the programming cable. If Dynamic C appears to compile the BIOS successfully, but you then receive a communi- cation error message when you compile and load the sample program, it is possible that your PC cannot handle the higher program-loading baud rate. Try changing the maximum download rate to a slower baud rate as follows. • Locate the Serial Options dialog in the Dynamic C Options > Project Options > Communications menu. Select a slower Max download baud rate. If a program compiles and loads, but then loses target communication before you can begin debugging, it is possible that your PC cannot handle the default debugging baud rate. Try lowering the debugging baud rate as follows. • Locate the Serial Options dialog in the Dynamic C Options > Project Options > Communications menu. Choose a lower debug baud rate. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |